![background image](http://html.mh-extra.com/html/daikin/altherma-ekhbh-series/altherma-ekhbh-series_service-manual_501281018.webp)
Specifications
ESIE06-03
1–18
3
11
4
5
2.3
EKHBH and EKHBX
Technical
specifications
The table below contains the technical specifications.
Specification
EKHBH*
EKHBX*
EKHBH007A* EKHBH007A* EKHBH007A*
EKHBX007*
EKHBX007*
EKHBX007*
Outdoor units
ERYQ005A
ERYQ006A
ERYQ007A
ERYQ005A
ERYQ006A
ERYQ007A
Nominal input (indoor only without electric heater)
230 W
Casing
Colour
RAL9010
Material
Epoxy polyester painted galvanised steel
Dimensions
Packing Height
1225
mm
Width
660 mm
Depth
595 mm
Unit
Height
895 mm
936 mm
Width
487 mm
487 mm
Depth
361 mm
461 mm
Weight
Machine weigth
55 kg
65 kg
Gross weight
65 kg
75 kg
Packing
Material
EPS/Wood/Carton/PS (straps)
Weight
10 kg
10 kg
Main components
Pump
Type
Water cooled
Nr. of speed
3
Nominal ESP unit Cooling
—
—
—
49.9 kPa
46.5 kPa
44.4 kPa
Nominal ESP unit Heating
46.5 kPa
40.1 kPa
29.0 kPa
46.5 kPa
40.1 kPa
29.0 kPa
Power input
130 W
Water side Heat exchanger
Type
Brazed plate
Quantity
1
Water volume
0.67 l
Water flow rate Min.
12 l/min
12 l/min
12 l/min
12 l/min
12 l/min
12 l/min
Water flow rate Nom. Cooling
—
—
—
14.7 l/min
16.5 l/min
17.6 l/min
Water flow rate Nom. Heating
16.5 l/min
19.6 l/min
24.2 l/min
16.5 l/min
19.6 l/min
24.2 l/min
Water flow rate Max. Cooling
—
—
—
—
—
—
Water flow rate Max. Heating
—
—
—
—
—
—
Insulation material
Polyurethane foam
Expansion vessel
Volume
10 l
Max. water pressure
3 bar
Pre-pressure
1 bar
Water filter
Diameter perforations
1 mm
Material
Brass
Water circuit
Piping connections diameter
1” MBSP
Piping
1” MBSP
Safety valve
3
Manometer
Yes
Drain valve/Fill valve
Yes
Shut off valve
Yes
Air purge valve
Yes
Refrigerant ciruit
Gas side diameter
15.9 mm
Liquid side diameter
(2)
Sound level
Sound pressure
27 dBA
Sound power
—
Operation range
Waterside
Cooling
7~20°C
Heating
30~55°C
Summary of Contents for Altherma EKHBH Series
Page 2: ...ESIE06 03 1 2 Part 1 System Outline 3 1 1 5 ...
Page 26: ...Functional Diagrams ESIE06 03 1 26 Part 1 System Outline 3 1 1 4 5 ...
Page 32: ...Piping Diagrams ESIE06 03 1 32 Part 1 System Outline 3 1 1 4 5 ...
Page 38: ...Switch Box Layout ESIE06 03 1 38 Part 1 System Outline 3 1 1 4 5 ...
Page 58: ...PCB Layout ESIE06 03 1 58 Part 1 System Outline 3 1 1 4 5 ...
Page 60: ...ESIE06 03 2 2 Part 2 Functional Description 3 1 2 5 ...
Page 68: ...Hydro box Functional Concept ESIE06 03 2 10 Part 2 Functional Description 3 1 2 4 5 ...
Page 88: ...ESIE06 03 3 2 Part 3 Troubleshooting 3 1 3 5 ...
Page 134: ...Error Codes System Malfunctions ESIE06 03 3 48 Part 3 Troubleshooting 3 1 3 4 5 ...
Page 152: ...Additional Checks for Troubleshooting ESIE06 03 3 66 Part 3 Troubleshooting 3 1 3 4 5 ...
Page 154: ...ESIE06 03 5 2 Part 5 Disassembly and Maintenance 3 1 5 ...