4
|
About the box
Installer reference guide
26
ERLA11~W1 + EBVH16SU23DJ
Daikin Altherma 3 R F
4P655196-1 – 2021.09
g
General safety precautions
h
Addendum book for optional equipment
i
Indoor unit installation manual
j
Operation manual
k
Sealing rings for shut-off valves (space heating water circuit)
l
Sealing rings for field-supplied shut-off valves (domestic hot water circuit)
m
Sealing tape for low voltage wiring intake (66×80 mm)
n
Antisweat sticker to cover the hole at the back of the unit (50×80 mm)
4.3.3 To handle the indoor unit
Use the handles at the back and at the bottom to carry the unit.
b
a
a
b
a
Handles at the back of the unit
b
Handles at the bottom of the unit. Carefully tilt the unit to the back so that the
handles become visible.
4.4 Domestic hot water tank kit
4.4.1 To remove the accessories from the domestic hot water tank kit
d
b
a
c
e
g
f
a
Pressure reducing valve/pressure relief valve combination. Water inlet and water
outlet 22 mm connection, discharge piping connection 15 mm
b
Adaptor 22 mm×3/4" Female BSP
c
T-piece 22 mm×22 mm×22 mm
d
Tundish 15 mm inlet, 22 mm outlet
e
Wall mounting set for expansion vessel
f
Instruction sheet
g
Expansion vessel of 18 l – 3/4" Male BSP
NOTICE
All piping MUST be installed according to section G3 of the Building Regulations.