![Daikin Altherma 3 R F Installer'S Reference Manual Download Page 300](http://html.mh-extra.com/html/daikin/altherma-3-r-f/altherma-3-r-f_installers-reference-manual_501204300.webp)
4/13
Breadcrumb Field code
Setting name
Range, step
Default value
Date
Value
Field settings table
Installer setting at variance with
default value
5.7.2
[2-00]
R/W
0: Each day
1: Monday
2: Tuesday
3: Wednesday
4: Thursday
5: Friday
6: Saturday
7: Sunday
5.7.3
[2-02]
R/W
0~23 hour, step: 1 hour
1
5.7.4
[2-03]
R/W
[E-07]
≠
1:
55~75°C, step: 5°C
60°C
[E-07]=1:
60°C
60°C
5.7.5
[2-04]
R/W
[E-07]
≠
1:
5~60 min, step: 5 min
40 min
[E-07]=1:
40~60 min, step: 5 min
40 min
Tank
5.8
[6-0E]
R/W
[E-07]=0 or 7 (*3):
40~60°C, step: 1°C
60°C
[E-07]=1 (*4):
40~65°C, step: 1°C
60°C
[E-07]=3 or 8 (*3):
40~75°C, step: 1°C
75°C
[E-07]=5 (*3):
40~80°C, step: 1°C
80°C
5.9
[6-00]
R/W
2~40°C, step: 1°C
8°C
5.A
[6-08]
R/W
2~20°C, step: 1°C
10°C
5.B
R/W
0: Fixed
1: Weather dependent
└─
WD curve
5.C
[0-0B]
R/W
35~[6-0E]°C, step: 1°C
50°C
5.C
[0-0C]
R/W
45~[6-0E]°C, step: 1°C
55°C
5.C
[0-0D]
R/W
10~25°C, step: 1°C
15°C
5.C
[0-0E]
R/W
-40~5°C, step: 1°C
-10°C
Tank
5.D
[6-01]
R/W
0~10°C, step: 1°C
0°C
User settings
└─
Quiet
7.4.1
R/W
0: OFF
1: Manual
2: Automatic
7.4.3
R/W
0: Quiet
1: More Quiet
2: Most Quiet
└─
Electricity price
7.5.1
R/W
0,00~990/kWh
1/kWh
7.5.2
R/W
0,00~990/kWh
1/kWh
7.5.3
R/W
0,00~990/kWh
1/kWh
User settings
7.6
R/W
0,00~990/kWh
0,00~290/MBtu
1,0/kWh
Installer settings
└─
Configuration wizard
└─
System
9.1.3.2
[E-03]
R/O
3: 6V (*1)
4: 9W (*2)
9.1.3.3
[E-05]
[E-06]
[E-07]
R/W (*3)
R/O (*4)
No DHW (*3)
EKHW, small volume (*3)
Integrated (*4)
EKHW, big volume (*3)
EKHWP (*3)
3rd party, small coil (*3)
3rd party, big coil (*3)
9.1.3.4
[4-06]
R/W
0: Manual
1: Automatic(normal SH/DHW ON)
2: Auto red SH/DHW ON
3: Auto red SH/DHW OFF
4: SH ON/DHW OFF
9.1.3.5
[7-02]
R/W
0: Single zone
1: Dual zone
9.1.3.6
[E-0D]
R/O
0: No
1: Yes
9.1.3.7
[6-02]
R/W
0~10kW, step: 0,2kW
3kW (*3)
0kW (*4)
9.1.3.8
[C-02]
R/W
0: No
1: Bivalent through header
9.1.3.9
[D-07]
[E-07]=5
R/W (*4)
0: No
1: Yes
└─
Backup heater
Operation day
Start time
Tank setpoint
Duration
Maximum
Hysteresis
Hysteresis
Setpoint mode
Leaving water value for high ambient temp. for DHW WD curve.
Leaving water value for low ambient temp. for DHW WD curve.
High ambient temp. for DHW WD curve.
Low ambient temp. for DHW WD curve.
Margin
Activation
High
Medium
Level
Low
Gas price
BUH type
Domestic hot water
Emergency
Number of zones
Glycol filled system
BSH capacity (*3)
Bivalent
Solar
4P655201-1 - 2021.09
(*1) *6V_(*2) *9W_(*3) EBB*_(*4) EBV*_
(*5) *X*_(*6) *H*_(*7) *11*_(*8) *16*_
(*9) *SU*_(*10) *18*_(*11) *23*
Summary of Contents for Altherma 3 R F
Page 309: ...13 13 ...
Page 310: ......
Page 311: ......