![Daikin Altherma 3 R F Installer'S Reference Manual Download Page 16](http://html.mh-extra.com/html/daikin/altherma-3-r-f/altherma-3-r-f_installers-reference-manual_501204016.webp)
3
|
Specific installer safety instructions
Installer reference guide
16
ERLA11~W1 + EBVH16SU23DJ
Daikin Altherma 3 R F
4P655196-1 – 2021.09
3 Specific installer safety instructions
INFORMATION
EBVH16SU23DJ6V is a heating only model. Therefore, all references to cooling in this
document are NOT applicable.
Always observe the following safety instructions and regulations.
"4.2.1 To handle, unpack and remove accessories –
)
CAUTION
To avoid injury, do NOT touch the air inlet or aluminium fins of the unit.
)
CAUTION
If there is more than one leaving water zone, ALWAYS install a mixing valve station in
the main zone to decrease (in heating)/increase (in cooling) the leaving water
temperature when the additional zone has demand.
"7.1 Preparing the installation site"
)
WARNING
Follow the service space dimensions in this manual for correct installation of the unit.
▪
"17.1 Service space: Outdoor unit"
▪
"7.1.3 Installation site requirements of the indoor unit"
67].
WARNING
The appliance shall be stored in a room without continuously operating ignition
sources (example: open flames, an operating gas appliance or an operating electric
heater).
WARNING
DO NOT reuse refrigerant piping that has been used with any other refrigerant.
Replace the refrigerant pipes or clean thoroughly.
Special requirements for R32 (see
"7.1.4 Special requirements for R32
)
WARNING
▪
Do NOT pierce or burn refrigerant cycle parts.
▪
Do NOT use means to accelerate the defrosting process or to clean the
equipment, other than those recommended by the manufacturer.
▪
Be aware that R32 refrigerant does NOT contain an odour.
WARNING
The appliance shall be stored so as to prevent mechanical damage and in a well-
ventilated room without continuously operating ignition sources (example: open
flames, an operating gas appliance or an operating electric heater).