![Daikin Altherma 3 R F Installer'S Reference Manual Download Page 301](http://html.mh-extra.com/html/daikin/altherma-3-r-f/altherma-3-r-f_installers-reference-manual_501204301.webp)
5/13
Breadcrumb Field code
Setting name
Range, step
Default value
Date
Value
Field settings table
Installer setting at variance with
default value
9.1.4.1
[5-0D]
R/W (*1)
R/O (*2)
0: 230V, 1~ (*1)
1: 230V, 3~ (*1)
2: 400V, 3~ (*2)
9.1.4.2
[4-0A]
R/W
0: 1
1: 1/1+2
2: 1/2
3: 1/2 + 1/1+2 in emergency
9.1.4.3
[6-03]
R/W
0~10kW, step: 0,2kW
2kW (*1)
3kW (*2)
9.1.4.4
[6-04]
R/W
0~10kW, step: 0,2kW
4kW (*1)
6kW (*2)
└─
Main zone
9.1.5.1
[2-0C]
R/W
0: Underfloor heating
1: Fancoil unit
2: Radiator
9.1.5.2
[C-07]
R/W
0: LWT control
1: Ext RT control
2: RT control
9.1.5.3
R/W
0: Fixed
1: WD heating, fixed cooling
2: Weather dependent
9.1.5.4
R/W
0: No
1: Yes
9.1.5.5
R/W
0: 2-points
1: Slope-Offset
9.1.6
[1-00]
R/W
-40~5°C, step: 1°C
-10°C
9.1.6
[1-01]
R/W
10~25°C, step: 1°C
15°C
9.1.6
[1-02]
R/W
[9-01]~[9-00], step: 1°C
[2-0C]=0:
40°C
[2-0C]=1:
45°C
[2-0C]=2:
55°C
9.1.6
[1-03]
R/W
[9-01]~min(45, [9-00])°C, step: 1°C
25°C
9.1.7
[1-06]
R/W
10~25°C, step: 1°C
20°C
9.1.7
[1-07]
R/W
25~43°C, step: 1°C
35°C
9.1.7
[1-08]
R/W
[9-03]~[9-02]°C, step: 1°C
22°C
9.1.7
[1-09]
R/W
[9-03]~[9-02]°C, step: 1°C
[2-0C]=0:
18°C
[2-0C]=1:
5°C
[2-0C]=2:
18°C
└─
Additional zone
9.1.8.1
[2-0D]
R/W
0: Underfloor heating
1: Fancoil unit
2: Radiator
9.1.8.3
R/W
0: Fixed
1: WD heating, fixed cooling
2: Weather dependent
9.1.8.4
R/W
0: No
1: Yes
9.1.9
[0-00]
R/W
[9-05]~min(45,[9-06])°C, step: 1°C
25°C
9.1.9
[0-01]
R/W
[9-05]~[9-06], step: 1°C
[2-0D]=0:
40°C
[2-0D]=1:
45°C
[2-0D]=2:
55°C
9.1.9
[0-02]
R/W
10~25°C, step: 1°C
15°C
9.1.9
[0-03]
R/W
-40~5°C, step: 1°C
-10°C
9.1.A
[0-04]
R/W
[9-07]~[9-08]°C, step: 1°C
[2-0D]=0:
18°C
[2-0D]=1:
5°C
[2-0D]=2:
18°C
9.1.A
[0-05]
R/W
[9-07]~[9-08]°C, step: 1°C
22°C
9.1.A
[0-06]
R/W
25~43°C, step: 1°C
35°C
9.1.A
[0-07]
R/W
10~25°C, step: 1°C
20°C
└─
Tank
9.1.B.1
[6-0D]
R/W
0: Reheat only
1: sched.
2: Scheduled only
9.1.B.2
[6-0A]
R/W
30~[6-0E]°C, step: 1°C
55°C
9.1.B.3
[6-0B]
R/W
30~min(50, [6-0E])°C, step: 1°C
45°C
9.1.B.4
[6-0C]
R/W
30~min(50, [6-0E])°C, step: 1°C
45°C
9.1.B.6
[6-08]
R/W
2~20°C, step: 1°C
10°C
└─
Domestic hot water
Voltage
Configuration
Capacity step 1
Additional capacity step 2
Emitter type
Control
Setpoint mode
Schedule
Low ambient temp. for LWT main zone heating WD curve.
High ambient temp. for LWT main zone heating WD curve.
Leaving water value for low ambient temp. for LWT main zone heating WD curve.
Leaving water value for high ambient temp. for LWT main zone heating WD curve.
Low ambient temp. for LWT main zone cooling WD curve.
High ambient temp. for LWT main zone cooling WD curve.
Leaving water value for low ambient temp. for LWT main zone cooling WD curve.
Leaving water value for high ambient temp. for LWT main zone cooling WD curve.
Emitter type
Setpoint mode
Schedule
Leaving water value for high ambient temp. for LWT add zone heating WD curve.
Leaving water value for low ambient temp. for LWT add zone heating WD curve.
High ambient temp. for LWT add zone heating WD curve.
Low ambient temp. for LWT add zone heating WD curve.
Leaving water value for high ambient temp. for LWT add zone cooling WD curve.
Leaving water value for low ambient temp. for LWT add zone cooling WD curve.
High ambient temp. for LWT add zone cooling WD curve.
Low ambient temp. for LWT add zone cooling WD curve.
Heat up mode
Comfort setpoint
Eco setpoint
Reheat setpoint
WD curve type
Reheat hysteresis
(*1) *6V_(*2) *9W_(*3) EBB*_(*4) EBV*_
(*5) *X*_(*6) *H*_(*7) *11*_(*8) *16*_
(*9) *SU*_(*10) *18*_(*11) *23*