ENGLISH
86
GB
7.4.3 - VP: Pressure display
Plant pressure measured in [bar] or [psi] depending on the measuring sys
-
tem used.
7.4.4 - VF: Flow display
Displays the flow in the chosen unit of measure. The measuring unit may
be [l/min] o [gal/min] vedi par. 7.5.4 - MS: Measuring system.
7.4.5 - PO: Absorbed power display
Power absorbed by the electropump in [kW].
A flashing round symbol may appear under the symbol of the measured
power PO. This symbol indicates the pre-alarm for exceeding the allowed
maximum power.
7.4.6 - C1: Phase current display
Motor phase current in [A].
A flashing round symbol may appear under the symbol of the phase cur
-
rent C1. This symbol indicates the pre-alarm for exceeding the allowed
maximum current. If it flashes at regular intervals it means that the motor
overload protection is about to trip and it will very probably go into protec
-
tion status.
7.4.7 - RS: Rotation speed display
Motor rotation speed in rpm.
7.4.8 - TE: Dissipator temperature display
7.5 - Installer Menu
From the main menu, hold down simultaneously the “MODE” and “SET”
and “-“ keys until the first parameter of the installer menu appears on the
display (or use the selection menu pressing + or -). The menu allows
you to view and modify various configuration parameters: the MODE key
allows you to scroll through the menu pages, the + and – keys allow you re
-
spectively to increase and decrease the value of the parameter concerned.
Press SET to leave this menu and return to the main menu.
7.5.1 - RP: Setting the pressure fall to restart
Expresses the fall in pressure with respect to the SP value which causes
restarting of the pump.
For example if the setpoint pressure is 3.0 [bar] and RP è 0.5 [bar] the
pump will restart at 2.5 [bar].
RP can be set from a minimum of 0.1 to a maximum of 1 [bar]. In particular
conditions (for example in the case of a setpoint lower than the RP) it may
be limited automatically.
To assist the user, on the RP setting page the actual restarting pressure
also appears highlighted under the RP symbol, see Figure 17.
7.5.2 - OD: Type of plant
VPossible values 1 and 2 referring to a rigid system and an elastic system.
The device leaves the factory with mode 1 suitable for the majority of sys
-
tems. In the presence of swings in pressure that cannot be stabilised by
adjusting the parameters GI and GP, change to mode 2.
7.5.3 - AD: Address configuration
This is significant only in a multi-pump connection. Set the communication
address to be assigned to the device. The possible values are: automatic
(default) or manually assigned address.
The addresses set manually can have values form 1 to 4. The configura
-
Figura 17: Setting the restart pressure
IMPORTANT:
The regulating parameters GP and GI also change in
the two configurations. In addition the GP and GI values set in mode
1 are stored in a different memory from the GP and GI values set in
mode 2. So, for example, when passing to mode 2, the GB value of
mode 1 is replaced by the GB value of mode 2 but it is kept and will
reappear again when returning to mode 1. The same value shown on
the display has a different weight in one mode or in the other because
the control algorithm is different.
Summary of Contents for E.sybox 50
Page 6: ......
Page 59: ...ITALIANO IT 56...
Page 62: ......
Page 116: ......
Page 172: ......
Page 228: ......
Page 284: ......
Page 285: ...RU 282 IEC 364 CEI 64 2 1000 3 1 2 e sybox e sybox 30 50 e sybox...
Page 286: ...RU 283 6 1 A 2 2 3 1 2 3 4 5 6 B 10 3 C 4 4 2 1 IN 2 3 1 A B C D E F A B E F 1...
Page 287: ...RU 284 OUT D 1 OUT C 4 4 1 2 F 1 2 2 3 IN C 2 4 5 4 4 5 4 5 5 1 1 SP 3 0 RP 0 3 5 6 7...
Page 291: ...RU 288 10 E 270 200 2 1 1 F IN 7 F OUT 7 1 GAS 1 3 1 BSP 25 8 2 1 2 30 25 mm 25 mm 8...
Page 293: ...RU 290 2 2 1 IN 9 OUT 9 D OUT 2 9 2 1 GAS 8 2 2 2 90 10 4 4 10...
Page 294: ...RU 291 2 2 3 3_ 5 F 1 1 5 11 x4 x4 1 5 F 1 3 _ 5 3 8 8 e sybox 7 e sybox30 50 3 1...
Page 301: ...RU 298 6 128x240 POWER COMM ALARM 12 6 MODE 1 SET 12 3 EEprom SET 6 SET MODE 5 5 6...
Page 302: ...RU 299 5 5 5 2 2 7 8 1 2 6 1 MODE SET MODE 7 2 2...
Page 304: ...RU 301 FF AY AE AF I1 1 I2 2 I3 3 I4 4 O1 1 O2 2 FW RF PW...
Page 305: ...RU 302 6 2 14 MODE 8 8 15 14 13...
Page 306: ...RU 303 2 298 9 GO SB DIS F1 F3 F4 P1 1 P2 2 P3 3 P4 4 EE EEprom 9 6 3 14...
Page 307: ...RU 304 GO SB 15 15 10 6 4 PW 6 5 RF PW 7 7 1 MODE MODE 7 1 1 7 1 2 RS 7 1 3 VP 7 1 4 VF...
Page 308: ...RU 305 7 1 9 11 SB F 8 F SB 7 1 10 2 11 7 1 5 PO PO 7 1 6 C1 A C1 7 1 7 7 1 8 PI 5 16...
Page 324: ...RU 321 6 7 9 9 1 6 1 2 1 2 3 18 4 5...
Page 325: ...RU 322 9 2 DAB 19 9 3 DAB 20 19 3 4 5 6 18...
Page 331: ...RU 328 1 3 C 1 1 1 4 D E 9 3 F 10 3 10 2 1 2 3 4 5 1 E 2 5 26 24 25...
Page 332: ...RU 329 6 10 3 1 27 2 F 10 1 27 3 27 4 27 5 6 2 D F 27 7 27 27 1 2 3 4 5 6...
Page 336: ...RU 333 12 10 4 3 2 SP RP 6 7 8 9 1 2 3 1 1 2 3 1 2 1 2 10 3 1 2 SP RP 1 2...
Page 337: ...RU 334 BL 1 2 3 RM 1 2 3 RM BP1 1 1 OC 1 2 1 2 PB 1 2 1 2 13 14...
Page 340: ......
Page 394: ......
Page 448: ......
Page 501: ...ROM N RO 498...
Page 504: ......
Page 505: ...GR 502 IEC 364 CEI 64 2 1000 Kg m3 1mm2 s i e sybox e sybox 30 50 e sybox H...
Page 506: ...GR 503 1 6 1 2 2 3 1 2 3 4 5 6 10 3 C 4 4 2 1 OUT 2 3 A B C D E F 1 A B E F...
Page 513: ...GR 510 2 2 1 C 9 C OUT 9 D OUT2 9 2 1 GAS e 8 2 2 2 90 10 4 4 10...
Page 514: ...GR 511 2 2 3 3_ 5 F 1 1 5 1 5 11 x4 x4 F 1 3_ 5 3 8 bar 8 e sybox 7 e sybox 30 50 3 1...
Page 522: ...GR 519 Setpoint 2 5 5 5 2 2 7 8 1 2 6 1 MODE SET Setpoint MODE 7 ONOMA TOY MENOY 2...
Page 540: ...GR 537 F4 KIWA Ix Ix 10 F4 11 C F4 12 F4 8 C F3 9 7 6 15 5 KIWA 18 Ix 1 7 6 2 1 F4 F4 2 18 17...
Page 545: ...GR 542 9 2 DAP 19 9 3 DAB 19 6 O ring 7 18 3 4 5 6...
Page 551: ...GR 548 C 1 1 1 4 D 9 3 24 25 F 10 3 10 2 1 2 3 4 5 1 2 5 6 26...
Page 552: ...GR 549 10 3 1 27 2 F 10 1 27 3 27 4 27 5 6 2 O Ring D F 27 7 27 27 1 2 3 4 5 6...
Page 556: ...GR 553 10 4 3 2 SP RP 1 2 3 4 1 2 3 1 1 2 3 1 2 1 2 10 3 1 2 SP RP 1 2...
Page 557: ...GR 554 BL 1 2 3 setpoint RM 1 2 3 RM setpoint BP1 1 1 OC 1 2 1 2 PB 1 2 1 2 13 14...
Page 560: ......
Page 616: ......
Page 669: ...T RK E TR 666...
Page 672: ......
Page 728: ......
Page 781: ...ESKY CZ 778...
Page 784: ......
Page 838: ......
Page 839: ...BG 836 1000 1 e sybox e sybox 30 50 e sybox IEC 364...
Page 841: ...BG 838 1 1 4 4 5 SP 3 0 bar RP 0 3 bar 5 6 7 5 6 7 1 2 2 SP RP 6 7 3 1...
Page 846: ...BG 843 270 B 200 A 10 D 2 2 1 C IN 9 C OUT 1 9 D OUT 2 9 1 GAS 8 2 2 2 0 90 10 4 4 4 10...
Page 847: ...BG 844 2 2 3 F 1 1 5 1 5 F 3 3_ 5 11 x4 x4 3 8 8 e sybox 7 e sybox30 50 3 1 A...
Page 854: ...BG 851 5 5 wireless wireless 8 2 1 2 6 1 MODE SET MODE 7 2 2 5 5 5 2 2 7...
Page 856: ...BG 853 FF Log AY AE AF I1 1 I2 2 I3 3 I4 4 O1 1 O2 Funzione uscita 2 FW RF PW...
Page 858: ...BG 855 2 76 9 GO SB DIS F1 F3 F4 P1 1 P2 2 P3 3 P4 4 E EE EEprom 9 6 3 rpm psi kW 14...
Page 874: ...BG 871 1 2 1 2 3 O 18 4 5 t O 6 7 18 3 4 5 6...
Page 875: ...BG 872 9 2 DAB 19 9 3 DAB 19 20 9 4 9 4 1 wireless 4 r 9 4 2 20...
Page 881: ...BG 878 27 7 27 27 1 2 3 4 5 6 10 4 1 27 2 3 4 10 5 1 2...
Page 884: ...BG 881 1 2 3 1 1 2 3 1 2 1 2 10 3 1 2 12 off t off 10 4 3 2 SP RP 1 2 3 4...
Page 885: ...BG 882 13 14 SP RP 1 2 BL 1 2 3 RM 1 2 3 RM BP1 1 1 OC 1 2 1 2 PB 1 2 1 2...
Page 886: ...BG 883...
Page 889: ......
Page 890: ...887 1mm2 s kg m 1000...
Page 891: ...888 A 1 2 3 4 5 6 B 4 C 1 1 B C D E F B E F 3 2...
Page 892: ...889 IN OUT D C 4 E 2 F 1 1 bar 0 SP 3 bar 3 RP 0 5 6 7 1 2 2 5 4 4...
Page 897: ...894 270 B 200 A 10 D 2 2 1 OUT 1 IN C 9 OUT 2 D GAS 2 2 2 90 4 4 10...
Page 898: ...895 2 2 3 1 5 3 8 7 8 3 1 A 3 2 11 x4 x4...
Page 899: ...896 SP RP 10 1 2 7 3 0 0 3 27 3 3 10 10 5 1 8 5 5 T2 4 3 2 1 E18 E19 E20 E21 Reset 15 PD FA...
Page 906: ...903...
Page 907: ...904 AY FF AE I1 1 I2 2 I3 3 I4 4 O1 1 O2 2 FW RF Reset PW Password...
Page 923: ...920 1 2 3 4 5 6 7 18 3 4 5 6...
Page 924: ...921 2 9 3 9 19 4 9 1 4 9 4 1 2 3 2 4 9 3 4 9 20...
Page 928: ...925 2 3 B 2 C 24 D 25 E 26 F 2 10 1 2 23 24 25 26...
Page 929: ...926 3 4 5 6 3 10 1 F 2 3 4 5 6 7 27 1 2 3 4 5 6...