Removing Boards
Precautions
Always wear an anti-static wrist strap when unplugging the module and the metallic part of the anti-static wrist strap
should be in full contact with the skin. Besides, for the sake of security, do not touch any component of the module.
Steps for Removing Boards
1)
Unplug all cables such as fibers and RJ-45 twisted pairs from the panel.
2)
Loosen the two captive screws on the panel.
3)
Remove the board by holding the ejector with both hands, as shown in Figure 3-33, 3-34, 3-35, 3-36.
4)
Install the blank panel in the slot to ensure system heat dissipation and avoid the dust if no new board will be
installed.
Always wear an anti-static wrist strap before plugging/unplugging a board.
Do not hold the edge of the PCB or collide the components on the PCB.
In order to ensure the reliability of the system ventilation and heat dissipation performance and address the
requirement of the dust-filter, blank module panel needs to be installed in the slot where no control module or service
module has been installed.
If you want to remove the board when the device is electrified, you need to insert the new board or install the blank
module panel within 10 minutes.
Figure 3-33 Board Components of the RG-S8614
Summary of Contents for RG-S8606 B
Page 1: ...RG S8600 Series Switch Hardware Installation and Reference Guide V1 78 ...
Page 58: ...Figure 2 3 Moving the RG S8606 Switch Figure 2 4 Moving the RG S8606 B Switch ...
Page 62: ...Figure 2 6 Ventilation of RG S8614 ...
Page 63: ...Figure 2 7 Ventilation of RG S8610 Figure 2 8 Ventilation of RG S8606 ...
Page 76: ...Figure 3 8 Installing the Power Supply of the RG S8606 Switch ...
Page 92: ...Figure 3 34 Board Components of the RG S8610 Figure 3 35 Board Components of RG S8606 ...
Page 116: ......