Note:
Modular layer: offers up to six module slots
Power layer: supports up to two AC or DC power supplies
Air outlet: Locates in the back of the chassis, the air-outlet unit of the
system.
The RG-
S8606 B’s hardware system is composed of the chassis, the power system, modules, the air filter and the
fan tray.
Chassis
RG-S8606 B has a standard 19-inch chassis, which is 311.5mm high, 436.8mm wide and 450mm deep. It consists of the
system modular layer, the fan layer and the power system layer.
The system modular layer is a module subrack that mechanically supports various modules of the RG-S8606 B. The
modular subrack is composed of module slots and the backplane.
At the top of the chassis are two power supply frames. The fan layer is at the back of the module subrack and houses four
fans working to suction air. And air filter is provided at the back.
Module Slot
The RG-S8606 B provides six module slots, of which two in the middle are only for the management modules. The four
slots on the top and the bottom can accommodate a mix of various modules. Modules are inserted horizontally in the
RG-S8606 B, with the same height of 412 mm, and depth of 350 mm.
When all the slots are occupied, the modules in the subrack of the RG-S8606 B are arranged as follows:
Two management modules as backup for each other
Four modules selected according to needs
The slots for the two management modules are in the middle and identified as M1 and M2 from top to bottom; the other
four line cards are numbered 1-4 from top to bottom.
Backplane
The RG-
S8606 B’s backplane interconnects high-speed data links from switch management board to module circuit board
and various management and control signals between modules. Its functions are as follows:
Interconnects all signals between modules and provide high-speed communication channel.
Passive backplane
Supports active/standby switching between management modules
Supports automatic identification of various slots
Implements distributed power supply
Introduces monitoring signal lines of the fan and power supply
Ventilation and Heat Dissipation System
The operating temperature of RG-S8606 B is 0 to 50°C. The thermal design must ensure that the surface temperature of
the components does not exceed 50% to 80% of the allowed maximum temperature and satisfy the requirement on the
device’s reliability in the temperature range while ensuring the device’s reliability, safety and maintainability.. According to
Summary of Contents for RG-S8606 B
Page 1: ...RG S8600 Series Switch Hardware Installation and Reference Guide V1 78 ...
Page 58: ...Figure 2 3 Moving the RG S8606 Switch Figure 2 4 Moving the RG S8606 B Switch ...
Page 62: ...Figure 2 6 Ventilation of RG S8614 ...
Page 63: ...Figure 2 7 Ventilation of RG S8610 Figure 2 8 Ventilation of RG S8606 ...
Page 76: ...Figure 3 8 Installing the Power Supply of the RG S8606 Switch ...
Page 92: ...Figure 3 34 Board Components of the RG S8610 Figure 3 35 Board Components of RG S8606 ...
Page 116: ......