Figure 1-8 Ventilation and Heat Dissipation System of the RG-S8606 B Switch
This structure is designed with air inlet from two sides, and air outlet at the back for modules, and air inlet through the
front plane and air outlet at the back for the power supply. The air flow direction is shown above. Four 120 x 120 x 38
fans are used to blow air outside for convection and ultimately heat dissipation. The chassis should be mounted in a
place with sufficient space for air circulation. Sufficient space (10 cm at least) must be reserved at the air intakes and
exhaust vents for ventilation.
Module
Refer to specifications of the products for the corresponding module types supported.
Summary of Modules
Module Type
Description
M8610/M8606-CM
As the switching and central control module of the RG-S8610/S8606, it manages the
entire system, including L2/L3 protocol processing, route management, user access
control and management, and network and operation maintenance.
M8610/M8606-CM II LITE
As the switching and central control module of the RG-S8610/S8606, it manages the
entire system, including L2/L3 protocol processing, route management, user access
control and management, and network and operation maintenance.
M8614/M8610/M8606-CM II
As the switching and central control module of the RG-S8614/S8610/S8606, it
largely enhances the processing capability of the processor on the basis of the
M8610/M8606-CM.The module manages the entire system, including L2/L3 protocol
processing, route management, user access control and management, and network
and operation maintenance.
M8610/M8606-CM III
As the switching and central control module of the RG-S8610/S8606, it upgrades the
bandwidth on the basis of the M8610/M8606-CM II. The module manages the entire
system, including L2/L3 protocol processing, route management, user access
control and management, and network and operation maintenance.
M8600-24SFP/12GT
It provides 12 SFP ports and 12 fiber/copper combo ports. The SFP ports support
the rate of 1000M, and the RJ-45 ports support auto-negotiation at 10/100/1000M.
The SFP optical modules support hot swapping.
M8600-24GT/12SFP
It provides twelve 10/100/1000BASE-T RJ45 ports and twelve fiber/copper combo
ports. The SFP ports support the rate of 1000M, and the RJ-45 ports support
auto-negotiation at 10/100/1000M. The SFP optical modules support hot swapping.
M8600-02XFP
It provides two 10G XFP ports. The XFP optical modules support hot swapping.
M8600P-24GT/12SFP
It provides twelve 10/100/1000BASE-T RJ45 ports and twelve fiber/copper combo
ports. The SFP ports support the rate of 1000M, and the RJ-45 ports support
auto-negotiation at 10/100/1000M and PoE function. The SFP optical modules
support hot swapping.
Summary of Contents for RG-S8606 B
Page 1: ...RG S8600 Series Switch Hardware Installation and Reference Guide V1 78 ...
Page 58: ...Figure 2 3 Moving the RG S8606 Switch Figure 2 4 Moving the RG S8606 B Switch ...
Page 62: ...Figure 2 6 Ventilation of RG S8614 ...
Page 63: ...Figure 2 7 Ventilation of RG S8610 Figure 2 8 Ventilation of RG S8606 ...
Page 76: ...Figure 3 8 Installing the Power Supply of the RG S8606 Switch ...
Page 92: ...Figure 3 34 Board Components of the RG S8610 Figure 3 35 Board Components of RG S8606 ...
Page 116: ......