M8600-16XS-DA
Module Appearance
Figure 1-43 Appearance of the M8600-16XS-DA
External Interface
The M8600-16XS-DA provides 16 SFP+ ports. The SFP+ ports support
10G SFP+ modules and Gigabit SFP modules.
Hot swapping of the
M8600-16XS-DA
, SFP and SFP+ modules is supported.
RG-M8600-16XS-DA
supports 10G SFP+ and Gigabit SFP modules. 10G SFP+ modules cannot be used as Gigabit
SFP modules.
LED
LED
Identification
on the panel
Status
Meaning
System LED
Status
Off
The module is NOT receiving power.
Solid red
The module is faulty.
Blinking
green
Initialization is in progress. Continuous blinking
indicates errors.
Solid green
The module is operational
SFP+ port LED
Link/ACT
Off
The port link is NOT connected.
Solid green
The port is connected.
Blinking
The port is transmitting and receiving data.
Specifications
Model
M8600-16XS-DA
Port type
16 SFP+ ports.
Transmission Medium
10GBASE-SR(850nm)
Multi-mode optical fiber
10GBASE-LR(1310nm)
Single-mode optical fiber
10GBASE-ER(1550nm)
Single-mode optical fiber
1000BASE-SX(850nm)
Multi-mode optical fiber
1000BASE-LX(1310nm)
Single-mode optical fiber
1000BASE-LH40(1310nm)
Single-mode optical fiber
1000BASE-ZX(1550nm)
Single-mode optical fiber
SFP+ copper cable (1m/3m/5m)
Passive copper cable
LED
Status, Link/ACT LEDs
Hot Swapping
Supported
Power Consumption
< 132W
EMC Standards
GB9254-2008
Safety Standards
GB4943-2011
Operating Temperature
0 to 40°C
Storage Temperature
-40 to 70°C
Operating Humidity
10% to 90% RH (non-condensing)
Weight
Net weight: 5.3 kg
Dimensions
( L x W x H)
436 mm x 346 mm x 45 mm
M8614/M8610/M8606-FAN/M8606-FAN B
The M8614-FAN is the fan module of the RG-S8614; the M8610-FAN is the fan module of the RG-S8610; the M8606-FAN
is the fan module of the RG-S8606; and M8606-FAN B is the fan module of the RG-S8606 B. M8614/M8610/M8606-FAN
forms a sound heat dissipation system of the entire system to ensure its stable operation.
Summary of Contents for RG-S8606 B
Page 1: ...RG S8600 Series Switch Hardware Installation and Reference Guide V1 78 ...
Page 58: ...Figure 2 3 Moving the RG S8606 Switch Figure 2 4 Moving the RG S8606 B Switch ...
Page 62: ...Figure 2 6 Ventilation of RG S8614 ...
Page 63: ...Figure 2 7 Ventilation of RG S8610 Figure 2 8 Ventilation of RG S8606 ...
Page 76: ...Figure 3 8 Installing the Power Supply of the RG S8606 Switch ...
Page 92: ...Figure 3 34 Board Components of the RG S8610 Figure 3 35 Board Components of RG S8606 ...
Page 116: ......