DGS-1100-06/ME Metro Ethernet Managed Switch CLI Reference Guide
91
DGS-1100-06/ME:5#
config syslog host
Purpose
To configure the syslog protocol to send system log data to a remote
host.
Syntax
config syslog host [all | <index 1-4>] {severity [informational |
warning | debug] | facility [local0 | local1 | local2 | local3 | local4
| local5 | local6 | local7] | state [enable | disable] | udp_port [ 514
| <udp_port_number 6000-65535>] | ipaddress [<ipaddr> |
<ipv6addr>]}
Description
The
config syslog host
command configures the syslog protocol to
send system log information to a remote host.
Parameters
all
− Specifies that the command applies to all hosts.
<index 1-4>
− Specifies that the command applies to an index of
hosts. There are four available indices, numbered 1 to 4.
severity
− The message severity level indicator. These are
described in the following table (Bold font indicates that the
corresponding severity level is currently supported on the Switch):
Numerical Severity
Code
0 Emergency: system is unusable
1 Alert: action must be taken immediately
2 Critical: critical conditions
3 Error: error conditions
4 Warning: warning conditions
5 Notice: normal but significant condition
6 Informational: informational messages
7 Debug: debug-level messages
informational
− Specifies that informational messages are to be sent
to the remote host. This corresponds to number 6 from the list
above.
warning
− Specifies that warning messages are to be sent to the
remote host. This corresponds to number 4 from the list above.
debug
− Specifies that debug message are to be sent to the remote
host.
facility
− Some of the operating system daemons and processes
have been assigned Facility values. Processes and daemons that
have not been explicitly assigned a Facility may use any of the
‘local
use
’ facilities or they may use the ‘user-level’ Facility. Those
Facilities that have been designated are shown in the following:
Bold font indicates the facility values that the Switch currently
supports.
Numerical Facility
Code
0 kernel messages