24
2) RS-232/IR:
This section controls the free routing behavior of the IR and
RS-232 streams as well as configuring the RS-232 settings.
Note: Independent routing control is only available via the optional IP
Master Controller hardware.
IR Setting:
Enable or disable the ability to freely route IR signals on
this unit. When free routing is disabled, the IR stream will follow the
video stream’s routing.
UART Setting:
Enable or disable the ability to freely route RS-232
signals on this unit. When free routing is disabled, the RS-232 stream
will follow the video stream’s routing.
Note: All connected units must have their UART configuration set the
same.
Baud Rate:
Set the baud rate. The available range is from 4800 to
115200 baud.
Stop Bit:
Set the number of stop bits. The available range is from 1 to
2.
Data Bit:
Set the number of data bits. The available range is from 5 to
8.
Parity:
Set the connection parity bit. The available options are: none,
odd, and even.
Flow Control:
Enable or disable flow control.