41
COMMAND
Description and Parameters
set uart 1 parity N1
Set the parity of the RS-232 port.
Available values for
N1
:
0
[None]
1
[Odd]
2
[Even]
get uart 1 parity
Show the current parity setting of the RS-232 port.
get webgui username
Show the current WebGUI login administrator username.
set webgui password N1
Set the WebGUI administrator password.
N1
= {Password}
[16 characters max]
get webgui password
Show the current WebGUI administrator password.
set telnet login N1
Enable or disable requiring a login to access the unit via Telnet.
Available values for
N1
:
ON
[Login
authentication
required]
OFF
[No
login
required]
get telnet login
Show the current state of the Telnet login requirement.
get hostname
Show the unit’s current hostname.
set webgui login timeout N1
Set the WebGUI inactivity timeout value.
Available values for
N1
:
0
[No
timeout]
1~30
[Timeout
in
minutes]