Mount the Control Valve
See
for a visual on mounting the control valve to the tank.
U-Clamp
Adapter
Inlet Strainer
U-Clamp
Tank Adapter O-Ring
1” Control Valve
Figure 5.
1.
The larger of the two o-rings in
the parts pack goes between the
adapter and the valve. Lubricate
o-ring on the tank adapter and
the outlet manifold o-ring with
silicone lubricant.
2.
Place the tank adapter o-ring
in the groove at the top of the
threads and DO NOT lubricate it.
3.
The inlet strainer must be threaded all
the way down against the outlet manifold
or the tank adapter won’t fit properly.
4.
Screw the adapter into the tank until
the adapter bottoms out on the tank
flange. The adapter only needs to be
hand-tightened to the tank flange. The
adapter must be tight, plastic against
plastic, with no gap to prevent the
tank o-ring from escaping.
5.
Align the manifold with the center
opening in the valve and press the
valve onto the adapter firmly. Be sure
to push the valve straight down onto
the manifold.
6.
Assemble the tank clamp to the
control and tighten the clamp screw.
NOTE!
The clamp and valve will be able to
rotate on the tank until pressure is
applied. Do not try to rotate control
valve if the clamp is tightened
otherwise you may cut the o-ring.