Installation
15
Culligan Aquasential Select Plus & Select Series Iron-OX5 & Sulfur-OX3 Water Filters 01040683
Plumbing Connections
•
Take the time to perform a clean installation. Foreign objects, if allowed to enter the piping, can enter the control
valve and cause operational problems.
•
Once the plumbing is connected to the bypass, the main water supply line may then be reopened so that unfiltered water
will be available to the household throughout the remainder of the installation process. Set the Cul-Flo-Valve Bypass in the
bypass position by screwing the stem all the way in against the body.
CAUTION!
Close the inlet supply line and relieve system pressure before cutting into the plumbing! Flooding
could result if not done!
CAUTION!
When making sweat con nec tions, remove all plastic and rubber components which contact brass or copper.
Damage to these components may result from heating solder joints.
Figure 9.
Plumbing Connection - Top View
Outlet
Connection
Inlet
Connection