Installation
17
Culligan Aquasential Select Plus & Select Series Iron-OX5 & Sulfur-OX3 Water Filters 01040683
Drain Line Connection
Refer to
for drain line length and height limitations.
1.
Fasten the drain line to the elbow with the hose.
2.
Secure the drain line to prevent its movement during regeneration. When discharging into a sink or open floor drain,
a loop in the end of the tube will keep it filled with water and will reduce splashing at the beginning of each regeneration.
NOTE!
Waste connections or drain outlets shall be designed and constructed to provide for connection
to the sanitary waste system through an air gap as required by the local plumbing code.
The system and installation must comply with state and local laws and regulations.
Figure 10.
Table 3. Maximum Allowable Drain Line Length
Height of Discharge Above Floor Level Operating
Operating Pressure
0 ft (0 m)
2 ft (0.6 m)
4 ft (1.2 m)
6 ft (1.8 m)
8 ft (2.4 m)
10 ft (3 m)
30 psi (210 kPa)
60 ft (18 m)
50 ft (15 m)
30 ft (9 m)
15 ft (5 m)
Not allowable
Not allowable
40 psi (279 kPa)
100 ft (30 m)
90 ft (27 m)
70 ft (21 m)
50 ft (15 m)
30 ft (9 m)
12 ft (4 m)
50 psi (349 kPa)
145 ft (41 m)
115 ft (35 m)
80 ft (24 m)
80 ft (24 m)
60 ft (18 m)
40 ft (12 m)
60 psi (419 kPa)
Normal installation
100 ft (30 m)
100 ft (30 m)
85 ft (26 m)
60 ft (18 m)
80 psi (559 kPa)
Should not require more than
140 ft (43 m)
120 ft (37 m)
100 psi (699 kPa)
100 ft (30 m) of drain line
150 ft (46 m)
Drain Elbow
Hose Clamp
Drain Line
Flow Control
Threaded
Straight Adapter
O-ring
O-ring
Drain Line