29
Culligan Aquasential Select Plus & Select Series Iron-OX5 & Sulfur-OX3 Water Filters 01040683
Use of Bypass Valve
Depending on where the particular installation was made, the outside sill cocks may or may not be served by filtered water.
Ideally, all lines not requiring filtered water should be taken off upstream of the filter. This is not always possible, however,
due to the difficulty or expense of rearranging the piping.
Bypass the filter if:
1.
The outside lines do not bypass the filter and the water is to be used for lawn irrigation or other outside uses.
2.
Water is not used for several days.
3.
You wish to inspect or work on the valve or air draw system.
4.
A water leak from the valve is evident.
Three-Valve Bypass
(If provided)
To bypass, close the inlet and outlet valves, and open the bypass valve. Reverse the process to get filtered water
once again. Be sure to close the middle bypass valve completely to avoid mixing untreated water with filtered water.
CAUTION!
If the media tank is to remain attached to the control valve, close only the inlet valve, then open the bypass
valve. This will prevent pressure from increasing in the media tank due to warming. If the filter is leaking or
continuously running to the drain, turn the outlet valve off as well.
Care and Cleaning
Protect the operation and appearance of the water conditioner by following these precautions:
1.
Do not place heavy objects on top of the filter cover.
2.
Use only mild soap and warm water to clean the exterior of the unit. Never use harsh abrasive cleaners
or compounds which contain acid or bleach. Culligan recommends Simple Green or an equivalent cleaner.
3.
Protect the filter and drain line from freezing temperatures.
4.
Reset the time, if required, after any interruption of electrical power to keep the unit on its normal schedule.
Serial Numbers
The serial number label is temporarily taped to the media tank and needs to be permanently attached to the tank during
installation. The label now has a second serial number on a perforated strip that can be torn off and applied to the IQR form
instead of handwriting the number. Wipe a location on the tank with an alcohol towelette then affix the label. That location
could be near the tank collar, tank base, side shell near the tank base, or under the Culligan emblem of a Quadra-Hull tank.
Alternately, the label may also be applied to the dealer copy of the customer sale order documentation.
12/01/2020
S/N:
TC11407095
The tank serial number label
needs to be attached at the time of
installation on a clean dry location
on the outside of the tank.
The bottom portion of the label
can be removed, placed on the
IQR form, and recorded online.
NOTE!
Do not remove or destroy the serial number; it is referenced on request for warranty repair or replacement.
WARNING!
Disconnect all electrical power to the unit before servicing.
Bypass the unit and relieve system pressure before attempting to repair.