Dip Switch Definitions
The circuit board is shipped with all DIP switches in the off position. Prior to programming the controller some DIP
switches need to be moved to the ON position. Because each switch serves a specific purpose, please review the
following information, moving the required switches to an ON position. The definitions and purpose are as follows:
NOTE!
DIP switch #3, #4, and #7 MUST be set to the “ON” position for the Iron-OX5 and Sulfur-OX3 filters.
All other switches are set to “OFF.”
Switch #
Abbreviation
Definition
Purpose
1
R / T
Run / Test
Off - Allows controller to function in a normal,
operational mode.
On - Places controller in test mode to verify
operation of the board components &
software.
2
D / I
Delayed / Immediate
Off - Reconditioning Cycle will occur at
Delayed Time of Day upon a controller
receiving a valid reconditioning cycle
initiation signal.
On - Reconditioning Cycle shall occur
immediately upon a controller receiving a valid
reconditioning initiation signal, regardless of the
time of day.
3
SO / FI
Softener / Filter
Off - The unit shall be operated as a softener.
On -The unit shall function as a filter but
utilize program logic to time the air draw
cycle to recharge the air head.
4
- / TCB
Time Clock Back-up Disabled /
Enabled
Off - The time clock backup option is not enabled.
On - Allows the user to program the time
clock function of the control to initiate the
reconditioning cycle on a fixed interval. This
setting MUST be on for the Sulfur-OX3 filter.
5
E / M
English / Metric
Off - The unit will function in standard
English dimensions.
On - The unit will function in standard
metric dimensions.
6
12 / 24
12 Hour Clock / 24 Hour Clock
Off - All time keeping functions shall be
based on an AM/PM basis. The PM icon
shall be lit in the display as appropriate.
On - Time keeping functions shall work on
a 24-hour clock (military time). The AM/PM
display icons will be disabled.
7
.75” / 1”
3/4” / 1” Control
Off - 3/4” Medallist Control Valve
On - 1” Medallist Plus Control Valve
8
S / F
Standard Refill / Fast Refill
Not applicable for filter applications.