28
Culligan Aquasential Select Plus & Select Series Iron-OX5 & Sulfur-OX3 Water Filters 01040683
Start-Up
1.
Close the main water supply valve.
2.
Set the bypass valve to the bypass position.
3.
Ensure that all faucets at the installation site are closed.
4.
Direct the drain line discharge into a bucket where flow can be observed.
5.
Before plugging in the power supply open the control valve cover to access the circuit board and move
Dip Switch #3, #4, and #7 to the “ON” position then close the cover.
6.
Plug the power supply into a 120 Volt, 60 Hz, single-phase receptacle and program the settings. Refer to
the Programming section for an overview of circuit board programming. The program settings for this system can
be found in the Programming section and in Settings on page 19 of this manual.
7.
Once the circuit board is properly programmed open the main supply valve.
8.
Manually cycle the control valve into Cycle 1 (Backwash) position.
9.
While in the Cycle 1 position, slowly open the bypass valve, allowing the tank to fill until water flows to the drain.
10.
With the bypass valve fully open, watch the drain line discharge for signs of media. If particles appear, reduce
the flow. Increase the flow again when media no longer appears in the discharge.
11.
After the backwash runs clear, cycle the control to Cycle 2 (Air Draw) position to verify air draw
through the suction line.
12.
Step the control to Cycle 3 (Fast Rinse) position and check for leaks on the suction line as it pressurizes.
13.
When the drain runs clear, cycle the control back to H (Home) position, complete the installation and cleanup.
14.
Initiate an immediate reconditioning cycle before leaving the installation site to establish a proper
head of air in the filter tank.
CAUTION!
If a sudden rush of water enters the filter, some of the media could be forced into the control valve.
WARNING!
Although not normally necessary, should you need to disassemble any part of the control valve or remove
the control from the tank assembly or associated plumbing, depressurize the unit first closing the main
supply valve, then open a convenient faucet down stream from the water conditioner.
Before Leaving The Installation Site
1.
The water heater will hold unfiltered water for several days. Advise the customer that the existing water volume
in the tank will need to be used before the hot water is completely filtered. If filtered hot water is required
immediately, refer to the water heater owner’s manual for the proper method of draining the water heater.
2.
Explain the operation of the filter to the customer. Make sure the customer knows that there will be new sounds
associated with the reconditioning of the unit.
3.
Fill in the number of people, and then sign and date the corresponding performance data sheet.
4.
Leave the Welcome Card with the customer.
5.
Attach the appropriate data plate label located in the Parts Pack onto the back of the control.
6.
Clean up the unit and installation site, removing any soldering, or pipe threading, residues from
the equipment and surrounding area with a damp towel.