Culligan Aquasential Select Plus & Select Series Iron-OX5 & Sulfur-OX3 Water Filters 01040683
Installation
18
Eductor Assembly Modifications for OX Systems
Refer to
and the following instructions for the required replacement of the eductor nozzle and throat
for OX systems.
1.
Remove the three screws and the eductor plate.
2.
Remove the eductor screen by lifting it from the eductor body.
3.
Remove the eductor body by grasping one of the projections with the pliers and gently pulling upward.
4.
Reverse the procedure to reassemble. Be certain that the replacement eductor body
contains the correct eductor nozzle.
Table 4. Eductor Selection
Model
Nozzle Color Throat
Nozzle with O-Ring P/N
10” Aquasential Select Plus Iron-OX5 or Sulfur-OX3
Green
Beige
P1024333 - 10 ea.
Backwash Flow Control
Refer to
and the following instructions for replacement of the drain line flow control:
1.
Remove the drain elbow retaining clip from the valve body.
2.
Pull the drain elbow from the valve body.
3.
Remove the flow control from the valve body and replace with a new flow restrictor.
NOTE!
The number on the backwash flow control should face into the valve body.
4.
Reverse the procedure to reassemble. Be certain that the replacement is the correctly sized flow restrictor.
Table 5. Backwash Flow Restrictor Selection
Model
Color & Number
P/N
10” Aquasential Select Plus Iron-OX5 or Sulfur-OX3
Black, 5.5 GPM
P0401031 - 10 ea.
Refer to
for a
visual on changing the
eductor nozzle and the
backwash flow control.
Eductor Screen
Eductor Nozzle
Eductor Throat
Drain Line
Flow Control
Drain Elbow
Figure 11.