Service Instruction
SI-6-18-12-C
Replaces SI-6-18-12-B
130526 THREE STAGE FILTER WITH REGULATORS
130526 ASSEMBLY
OUTLET
AIR
DRAIN
UNION
1/2 NPT
INLET AIR
REPLACEMENT
INDICATOR
RECOMMENDED INSTALLATION
DESCRIPTION
The three stage filter unit, with two self-
relieving regulators, is designed to be a
point of use system. It is designed to
provide clean air for a paint spray gun,
breathable air unit and waterborne paint
dryers. It is capable of removing dirt,
water, oil, liquid aerosols, sub-micron
particles, oil vapors and odors.
SPECIFICATIONS
Air Flow: 65 SCFM @ 90 PSIG
Max. Pressure: 150 PSIG
Max. Temperature: 150°F
Regulated Pressure Range: 2-125 psig
BREATHING AIR REQUIREMENTS
Supplied breathing air, as defined by
OSHA 29 CFR 1910.134(i), NIOSH 42 CFR
84.141, and CSA CAN 3-Z180.1-00 MUST
meet or exceed the following requirements
for Type 1-Grade D breathable air, as
defined in Compressed Gas Association
(CGA-G7-1-1997):
Risk of illness or death. Carbon monoxide
can cause nausea, fainting or death. Stop
using if carbon monoxide is present. This
unit does not remove carbon monoxide. A
carbon monoxide monitor should be incor-
porated into your air supply line to warn of
the presence of carbon monoxide.
It is up to the employer to assure that the
air compressor is properly maintained, that
the air compressor intake is located in a
clean contaminate free location and that
the air compressor is drawing in typical
atmospheric air, meeting all of the national
and local requirements for breathing air.
OK
REPLACE
ELEMENT
1
ST
STAGE
Liquid & dirt
removal
40 microns
Replace
element
every
3 months
CHECK WITH
AIR FLOWING
OUTLET
AIR
1/4 NPSM
OUTLET
1/4 NPSM
OUTLET
2
ND
STAGE
Liquid aerosol
& sub-micron
particle
removal
0.01 microns
Replace
element
when
indicator is
raised halfway
3
RD
STAGE
Charcoal
adsorber
Oil vapor &
odor removal
Replace
element every
six weeks
(or sooner
if odors
are present)
This filter unit does not remove or filter
Carbon Monoxide (CO). It is up to the
employer to ensure that the level of CO
does not exceed the maximum national or
local allowed level. The recommended
method to assure that the CO level is not
exceeded is to install a carbon monoxide
monitor and alarm.
This filter unit will only remove particulate
matter, water, oil and odor. This filter unit
will meet the particulate matter, oil and
odor requirements of Type 1-Grade D
Breathable Air and Compressed Breathing
Air, CSA-Z180.1 when:
• The filter unit is connected to a
compressed air source:
° The compressor is properly main-
tained
Contaminant
OSHA
CSA
Oxygen
19.5-23.5%
20-22%
Carbon Monoxide
(ppm v/v)
10
<5m L/m
3
Carbon Dioxide
(ppm v/v)
1,000
500m L/m
3
Oil (Condensed
Hydrocarbons)
mg/m
3
5
1mg/m
3
Odor
“lack of
noticable
odor”
“free of any
detectable
odor”
° The air compressor intake is located
in a clean contaminate free location
° The air compressor is drawing in
typical atmospheric air, meeting all of
the national and local requirements
for breathing air
• The filters are properly maintained
• A properly operating CO monitor is
installed