background image

Service Instruction

SI-6-18-12-C

Replaces SI-6-18-12-B

130526 THREE STAGE FILTER WITH REGULATORS

130526 ASSEMBLY

OUTLET

AIR

DRAIN

UNION

1/2 NPT

INLET AIR

REPLACEMENT

INDICATOR

RECOMMENDED INSTALLATION

DESCRIPTION

The  three  stage  filter  unit,  with  two  self-

relieving  regulators,  is  designed  to  be  a

point  of  use  system.  It  is  designed  to

provide  clean  air  for  a  paint  spray  gun,

breathable  air  unit  and  waterborne  paint

dryers.  It  is  capable  of  removing  dirt,

water,  oil,  liquid  aerosols,  sub-micron

particles, oil vapors and odors.

SPECIFICATIONS

Air Flow: 65 SCFM @ 90 PSIG

Max. Pressure: 150 PSIG

Max. Temperature: 150°F

Regulated Pressure Range: 2-125 psig

BREATHING AIR REQUIREMENTS

Supplied  breathing  air,  as  defined  by

OSHA  29  CFR  1910.134(i),  NIOSH  42  CFR

84.141,  and  CSA  CAN  3-Z180.1-00  MUST

meet or exceed the following requirements

for  Type  1-Grade  D  breathable  air,  as

defined  in  Compressed  Gas  Association

(CGA-G7-1-1997):

Risk of illness or death. Carbon monoxide

can cause nausea, fainting or death. Stop

using if carbon monoxide is present. This

unit does not remove carbon monoxide. A

carbon monoxide monitor should be incor-

porated into your air supply line to warn of

the presence of carbon monoxide.

It is up to the employer to assure that the

air compressor is properly maintained, that

the  air  compressor  intake  is  located  in  a

clean  contaminate  free  location  and  that

the  air  compressor  is  drawing  in  typical

atmospheric air, meeting all of the national

and local requirements for breathing air.

OK

REPLACE

ELEMENT

1

ST

STAGE

Liquid & dirt

removal

40 microns

Replace

element 

every 

3 months

CHECK WITH

AIR FLOWING

OUTLET

AIR

1/4 NPSM

OUTLET

1/4 NPSM

OUTLET

2

ND

STAGE

Liquid aerosol

& sub-micron

particle

removal

0.01 microns

Replace

element 

when 

indicator is

raised halfway

3

RD

STAGE

Charcoal

adsorber

Oil vapor &

odor removal

Replace

element every

six weeks 

(or sooner 

if odors 

are present)

This  filter  unit  does  not  remove  or  filter

Carbon  Monoxide  (CO). It  is  up  to  the

employer  to  ensure  that  the  level  of  CO

does not exceed the maximum national or

local  allowed  level.  The  recommended

method to assure that the CO level is not

exceeded  is  to  install  a  carbon  monoxide

monitor and alarm.

This filter unit will only remove particulate

matter, water, oil and odor. This filter unit

will  meet  the  particulate  matter,  oil  and

odor  requirements  of  Type  1-Grade  D

Breathable Air and Compressed Breathing

Air, CSA-Z180.1 when:

• The  filter  unit  is  connected  to  a

compressed air source:

° The  compressor  is  properly  main-

tained

Contaminant

OSHA

CSA

Oxygen

19.5-23.5%

20-22%

Carbon Monoxide 

(ppm v/v)

10

<5m L/m

3

Carbon Dioxide 

(ppm v/v)

1,000

500m L/m

3

Oil (Condensed

Hydrocarbons)

mg/m

3

5

1mg/m

3

Odor

“lack of 

noticable 

odor”

“free of any

detectable

odor”

° The  air  compressor  intake  is  located

in a clean contaminate free location

° The  air  compressor  is  drawing  in

typical atmospheric air, meeting all of

the  national  and  local  requirements

for breathing air

• The filters are properly maintained

• A  properly  operating  CO  monitor  is

installed

Summary of Contents for 130526

Page 1: ...typical atmospheric air meeting all of the national and local requirements for breathing air OK REPLACE ELEMENT 1ST STAGE Liquid dirt removal 40 microns Replace element every 3 months CHECK WITH AIR FLOWING OUTLET AIR 1 4 NPSM OUTLET 1 4 NPSM OUTLET 2ND STAGE Liquid aerosol sub micron particle removal 0 01 microns Replace element when indicator is raised halfway 3RD STAGE Charcoal adsorber Oil vap...

Page 2: ...ed air service and use with any other fluid liquid or gas is a misapplication For example use with or injection of certain hazardous gases in the system such as oxygen or liquid petroleum gas could be harmful to the unit or result in a combustible condition that may cause fire or explosion Manufacturer s warranties are void in the event of misapplication and manufac turer assumes no responsibility...

Page 3: ...18 Filter Element Coalescing 4 130520 Indicator Kit Coalescing 5 VA 595 Shut off Valve 6 130527 Filter Element Charcoal 5 Snug tight Snug tight Hand tight plus 1 4 turn 4 PARTS LIST 3 2 1 Handtight plus 1 4 turn Lightly grease with enclosed lubricant Ref Replacement No Part No Description 1 130521 Regulator Kit 2 H 2008 Adapter 3 GA 288 Gauge 4 GA 375 Gauge Upside Down 4 Plug 1 1 1 1 2 3 6 ...

Page 4: ...ETAPA Eliminación de líquido y polvo 40 micrones Reemplace el elemento cada 3 meses REVISE CON EL AIRE FLUYENDO AIRE DE SALIDA 1 4 NPSM SALIDA 1 4 NPSM SALIDA 2a ETAPA Eliminación de aerosol líquido y partículas de submicrones 0 01 micrones Reemplace el elemento cuando el indicador haya subido a la mitad 3a ETAPA Adsorbedor de carbón Eliminación del vapor de aceite y los olores Reemplace el elemen...

Page 5: ...quier otro fluido líquido o gas es una aplicación indebida Por ejemplo su uso con o la inyección en el sistema de ciertos gases peligrosos como oxígeno o gas de petróleo líquido podría ser perju dicial para la unidad o producir una condición combustible que podría causar un incendio o explosión Las garantías del fabricante son nulas en caso de apli cación indebida y el fabricante no asume ninguna ...

Page 6: ...el indicador coalescente 5 VA 595 Válvula de cierre 6 130527 Elemento de filtro carbon 5 Apriete para que encaje bien Apriete para que encaje bien Apriete a mano dando un 1 4 de vuelta adicional 4 LISTA DE PIEZAS 3 2 1 Apriete a mano dando un 1 4 de vuelta adicional Engrase ligeramente con el lubricante adjunto Ref Refacción No No Descripción 1 130521 Kit del regulador 2 H 2008 Adaptador 3 GA 288 ...

Page 7: ...4 NPSM SORTIE 1 4 NPSM SORTIE 2E PHASE Retire les particules microniques et aérosols liquides 0 01 microns Remplacer l élé ment lorsque l indicateur s élève à la ligne médiane 3E PHASE Adsorbeur de charbon de bois Retire les vapeurs d huile et les odeurs Remplacer l élé ment toutes les six semaines ou plus souvent en présence d odeurs ment que l orifice d aspiration du compresseur d air se trouve ...

Page 8: ...utilisation avec tout autre fluide liquide ou gaz est interdite Par exemple l utilisation avec ou l injection dans le système de certains gaz nocifs tels que l oxygène ou le gaz de pétrole liquéfié peut être nocif à l unité ou entraîner un état combustible qui pour rait cause un incendie ou une explosion Les garanties du fabricants seront annulées en cas de mauvaise utilisation et le fabricant n a...

Page 9: ... du filtre coalescent 4 130520 Trousse de témoin coalescent 5 VA 595 Robinet d arrêt 6 130527 Trousse de témoin fusain 5 Bien resserrer Resserrer à la main plus 1 4 de tour 4 LISTE DES PIÈCES 3 2 1 Resserrer à la main plus 1 4 de tour Lubrifier légèrement avec le lubrifiant fourni Ref Replacement No Part No Description 1 130521 Trousse de régulateur 2 H 2008 Adaptateur 3 GA 288 Jauge 4 GA 375 Jaug...

Page 10: ...Page 10 SI 6 18 12 C NOTES NOTAS ...

Page 11: ...Page 11 SI 6 18 12 C NOTES NOTAS ...

Page 12: ... DeVilbiss sont couverts contre les vices de matériel et de fabrication par une garantie limitée d un an de Carlisle Fluid Technologies L utilisation de toutes pièces ou accessoires issus d une source autre que Carlisle Fluid Technologies annulera toutes les garanties Pour des informations précises sur la garantie veuillez contacter le site de Carlisle Fluid Technologies le plus proche que vous tr...

Reviews: