Culligan Aquasential Select Plus & Select Series Iron-OX5 & Sulfur-OX3 Water Filters 01040683
Preparation
8
Position the Media Tank
Determine the installation location and position the media tank prior to loading filter media. It may be difficult to move the tank
after media is loaded.
Figure 1.
Iron-OX5 and Sulfur-OX3 filter system placement.
Location
Set the media tank in the location where it will be installed.
Placement
Refer to
for system placement.
•
Set the media tank on a solid, level surface near water, drain and electrical facilities.
•
As you face the system, the inlet will be on the right and the outlet will be on the left.
Space Requirements
Allow 6-12 inches (15-30 cm) behind the unit for plumbing and drain lines and 4 feet (1.3 meters) above for service access.
Floor Surface
Choose an area with solid, level floor, free of bumps or irregularities.
Drain Facilities
Choose a nearby drain that can handle the rated drain flow (floor drain, sink or stand pipe).
NOTE!
Most codes require an anti-siphon device or air gap for the drain line. Observe all local plumbing codes and
drain restrictions. The system and installation must comply with all state and local laws and regulations.
Electrical Facilities
A wall mount plug-in power supply with a 20-foot cord is provided. The customer should provide an electrical outlet that is not
controlled by a switch that can be turned off accidentally. Observe local electrical codes. For Outdoor use with a UL Listed
Class 2 Direct Plug-in Power Unit only.