Thank you for purchasing your UV system, or your replacement quartz sleeve and lamp supplied by East 
Midlands Water Company.  

Please read through these instructions before carrying out your installation. 

 

 

 

 

 

 

ULTRA VIOLET (UV)       

WATER STERLISATION 

INSTALLATION and REPLACEMENT

 INSTRUCTIONS

 

Transformer with PVC cap 

Rubber o-ring 

(Please note this is packed in 

a plastic bag and attached to the flex on the 

transformer. This is to prevent the o-ring be-

ing lost in the packaging or being mislaid. 

DO NOT DISCARD THESE O-RINGS. 

They 

are reusable and chargeable if you dispose 

of them 

This is the 

stainless steel chamber

. You will need to 

mount this appropriately to your particular application by 

using the separate brackets (where supplied) or the ones 

that are part of the unit. The chamber will need to be 

plumbed into your water supply/connected to your 

plumbing using the connectors shown (or similar). 

Quartz sleeve and lamp. 

HANDLE WITH CARE

. They are 

MADE OF FRAGILE GLASS. 

Avoid touching the centre 

part of the sleeve/lamp. Pick up and handle by both ends. 
The photograph shows the rubber o-ring in place on the 
sleeve, approximately 2cm from the open end.  

The lamp.  This is filled with special incandescent  
bearings which when heated, fluoresce and are a vital part 
of the way the lamp operates.  The bearings move around 
inside the lamp and you may detect a slight ‘rattle’. This is 
completely normal 

Mounting brackets (may differ when 

using UV with other water treatment 

systems, such as RO’s) 

Please check that you have all your components before commencing installation. Missing or 

broken elements can only be replaced immediately on receipt of goods and upon proof of 

damage. You should have the following elements; 

Page 1 

NEW INSTALLATION   

 

 

 

 

 

ALL PAGES

 

REPLACING YOUR UV LAMP 

 

 

 

 

PAGES 2,3 AND 4

 

REPLACING YOUR QUARTZ SLEEVE  

PAGES 2 3 AND 4

 

UV 3.9 LPM SYSTEMS 

PTFE tape 

required 
on these 

joints 

Summary of Contents for UV 3.9 LPM

Page 1: ...to your plumbing using the connectors shown or similar Quartz sleeve and lamp HANDLE WITH CARE They are MADE OF FRAGILE GLASS Avoid touching the centre part of the sleeve lamp Pick up and handle by both ends The photograph shows the rubber o ring in place on the sleeve approximately 2cm from the open end The lamp This is filled with special incandescent bearings which when heated fluoresce and are...

Page 2: ...the chamber for 5 10 minutes before use 1 Disconnect the power supply 2 Turn the water off and open a tap down stream of the system to relieve the pressure 3 Remove the PVC cap and unscrew the aluminium nut 4 Carefully withdraw the lamp approximately 2cm from the chamber 5 While holding the lamp end carefully remove the lamp socket on the exposed end 6 Carefully withdraw the lamp from the chamber ...

Page 3: ...GHTEN Now connect the lamp to the socket DO NOT TOUCH THE LAMP WITH BARE HANDS AS THIS WILL AFFECT THE PERFORMANCE OF THE LAMP Connect by gently pushing the four pins of the lamp into the socket Gently position the lamp into the quartz sleeve through the open end of the stainless steel casing Push on the rubber cap seal and ensure that it is sitting correctly with no creases or kinks 2 3 4 6 1 2 3...

Page 4: ... Rubber o ring 6 Quartz sleeve 7 Stainless steel chamber 8 Elbow optional 9 Mounting bracket separate on some units 10 Transformer fitted with standard UK electrical plug Diagram of set up of UV water sterilisation system Page 4 For replacement UV lamps quartz sleeves and transformers please contact www eastmidlandswater com or call us on 0116 276 3334 ...