Chapter 4. Web Configuration & Operation
222
CHAPTER 4
WEB OPERATION & CONFIGURATION
4.4.7 Ports VeriPHY™
This page is used for running the VeriPHY™ Cable Diagnostics for 10/100 and 1G copper ports. Select which ports to
run, or all. Click "Start".
This will take approximately 5 seconds per port. If all ports are selected, this can take approximately 15 seconds.
When completed, the page refreshes automatically, and you can view the cable diagnostics results in the cable status
table. Note that VeriPHY is only accurate for cables of length 7 - 140 meters.
10 and 100 Mbps ports will be linked down while running VeriPHY. Therefore, running VeriPHY on a 10 or 100 Mbps
management port will cause the switch to stop responding until VeriPHY is complete.
Port:
Port number.
Pair:
The status of the cable pair.
OK:
Correctly terminated pair
Open:
Open pair
Short:
Shorted pair
Short A:
Cross-pair short to pair A
Short B:
Cross-pair short to pair B
Short C:
Cross-pair short to pair C
Short D:
Cross-pair short to pair D
Cross A:
Abnormal cross-pair coupling with pair A
Cross B:
Abnormal cross-pair coupling with pair B
Cross C:
Abnormal cross-pair coupling with pair C
Cross D:
Abnormal cross-pair coupling with pair D
Length:
The length (in meters) of the cable pair. The resolution is ±3 meters.
NOTE:
VeriPHY is only applicable to the electrical ports. It is not applicable to the optical ports.