Chapter 4 – Res-Intensity Calibration
Parameter
Range
Default
Do the following...
Start Value
300 - 4000
1000
Enter the value of the first intensity strip, for example,
2000.
End Value
1000 -11000 5000
Enter the value of the last intensity strip, for example,
10230.
Step Intensity
100 - 4000
500
Enter the value of the gap between intensity strips, for
example, 800.
Strip Height
10 -1000
20
Enter the height of the intensity strips in [mm], for
example, 5.
Strip Width
0 - 1180
700
Enter the width of the intensity strips in [mm], for
example, 100.
Cassette
-
SML
Toggle to the size of cassette currently used.
Move Carriage
-
Yes
Toggle this field to
Yes
to use
exposing
mode (that is,
not
simulation mode).
Load Media
-
Yes
Toggle this field to
Yes
to load film into the imagesetter
(that is,
not
simulation mode).
Spinner Speed
3000 - 14000 13800
Enter the speed of the spinner in [RPM], for example,
13800.
Note:
This resolution-dependent field affects the quality of
the exposure.