8.3.1 Parameter table
PARAMETER TABLE
Parameter
no.
Description
Range
Default
Notes
0
Set point temp. Heat Pump
10 ~ 70°C
50°C
Adjustable
1
Heat Pump activation temperature
hysteresis
2 ~ 15°C
5°C
Adjustable
2
E-heater off tank water temp
10 ~ 90°C
55°C
Adjustable
3
E-heater delay time
0 ~ 90min
6min
t * 5 min
4
Week disinfection temperature
50 ~ 70°C
70°C
Adjustable
5
High temp disinfection time
0 ~ 90 min
30 min
Adjustable
6
Defrosting period
30~90 min
45 min
Adjustable
7
Defrosting entry coil temp.
-30 ~ 0°C
-7°C
Adjustable
8
Defrosting exit coil temp.
2 ~ 30°C
13°C
Adjustable
9
Max defrosting cycle period
1 ~ 12 min
8 min
Adjustable
10
Electronic expansion valve adjustment
0/1
1
(0→ manual, 1→ auto).
keep always on 1 (auto).
11
Target over-heat degree
-9 ~ 9°C
5°C
Keep always default value.
12
Steps of manually adjusting the electronic
expansion valve
10 ~ 50 step
35 step
Keep always default value.
13
Disinfection start up time adjusting
0~23
23
Adjustable (hour)
A
Inlet water temp. “IN”
(lower T2 probe)
-9 ~ 99°C
Actual testing value. Error code PP1 will be shown in case
of a malfunction
B
Outlet water temp. “OUT”
(upper T3 probe)
-9 ~ 99°C
Actual testing value. Error code PP2 will be shown in case
of a malfunction
C
Evaporator coil temp.
(T4 probe)
-9 ~ 99°C
Actual testing value. Error code PP3 will be shown in case
of a malfunction
D
Return gas temp.
(T5 probe)
-9 ~ 99°C
Actual testing value. Error code PP4 will be shown in case
of a malfunction
E
Ambient temp.
(T1 probe)
-9 ~ 99°C
Actual testing value. Error code PP5 will be shown in case
of a malfunction
F
Electronic expansion valve step
10 ~ 47 step
Actual open degree of EEV N*10 step
H
Disinfection record
1~99
Every time it finish disinfection, the digital number will increase
one (after 99 it will reset to 0)
Summary of Contents for Bollyterm HP
Page 10: ...10 Cod 1910000001187 nv01 ESEMPI DI CANALIZZAZIONI Italiano...
Page 22: ...22 Cod 1910000001187 nv01...
Page 30: ...30 Cod 1910000001187 nv01 English EXAMPLES OF CHANNELING...
Page 42: ...42 Cod 1910000001187 nv01...
Page 50: ...50 Cod 1910000001187 nv01 Nederlands VOORBEELDEN VAN KANALISEREN...
Page 63: ...63 Cod 1910000001187 nv01...