Operational Performance Checks
Teledyne Continental Motors, Inc.
TM
NOTE: If a new engine emits a small puff of smoke immediately
upon engine start-up, there may have been a small amount of
preservation oil remaining in the cylinders, induction system,
and/or fuel nozzles/lines. The smoke should quickly dissipate; if
smoke persists, shut down the engine (“Engine Shutdown” in
Chapter 7 of the TCM Installation and Operation Manual (OI-22))
and investigate the cause.
13.
HSA......................................................................Check
RESULT: No persistent FADEC Annunciator lamp illuminations. If a lamp is lit,
address the cause.
CAUTION: Operating the engine without oil pressure will result in
engine malfunction or stoppage.
NOTE: The IOF-240-B engine incorporates a fixed oil pressure
relief valve; oil pressure is not adjustable. If oil pressure drops
below the specified operating pressure at idle (10psig) or normal
operation (30 to 60 psig), remove the oil pressure relief cap and
inspect the plunger, seat and spring according to instructions in the
TCM Overhaul Manual (OH-22). Reface the pressure relief valve
seat or replace the plunger and seat, as required.
14.
Oil pressure ..........................................................Check
RESULT: Oil pressure indicates 30-60 psi. If no oil pressure is noted, shut down the
engine and investigate the cause.
15.
Throttle ................................................................850 RPM (idle speed)
RESULT: Maintain idle speed for 1 minute.
16.
Fuel Selector ........................................................ON, Fullest tank or BOTH
WARNING
Do not operate the engine at speeds above 1700 RPM until the
oil temperature is at least 75
°
F (24
°
C) and the oil pressure is
within the normal operating range. Operating at speeds above
1700 RPM before reaching the minimum oil temperature may
result in engine malfunction or engine failure.
17.
Throttle.................................................................1700 RPM
RESULTS: Alternator output is equal to or greater than the electrical system’s rated
output according to the AFM/POH. FADEC CAUTION and WARN lamps are OFF.
6-8
IOF-240 Series Engine Maintenance Manual
NOTE: If the Ignition Switch is left in the L or R position (steps 18
and 20) for more than 30 seconds, the FADEC WARN lamp will
illuminate. Turn the Ignition Switch to the BOTH position
momentarily to clear the fault.
Change 1
31 August 2007