![Conductix-Wampfler MultiLine 0835 Mounting Instruction Download Page 72](http://html1.mh-extra.com/html/conductix-wampfler/multiline-0835/multiline-0835_mounting-instruction_2651966072.webp)
Mounting Instruction
Conductor rail system
MultiLine 0835
MAL0835-0001c-EN
www.conductix.com
translated document
page 72 of 81
CAUTION!
Take the requisite measures to prevent this risk!
→
Fit a contact guard that will safely cover the sliding contact if it sticks out of the conductor rail!
10.1
Fault remedy table
Fault
Cause
Corrective measures
The sliding contacts show
uneven wear.
The current collector heads' range of movement
is restricted.
Only use original Conductix-Wampfler
current collectors, check cable position
(make sure cables can move freely).
Contact pressure is too high or low.
Install current collector as specified in
Fig. 45; use highly flexible class 6
connecting cables (in accordance with
ICE 602228).
The sliding contact
insulation on the side has
been worn away down to
the
sliding contact.
If installed horizontally: The current collector's height
has not been correctly adjusted.
Replace current collector heads; move
the current collector to the correct
height (see Fig. 45 and Fig. 46).
Sliding contacts are
wearing too fast.
Sharp edges on the power terminal, conductor rails,
connections between the conductor rails
Smoothen sharp edges with a file, air
file or sanding paper.
Conductor rails dirty or scorched in places.
Check current values; clean rails as
specified in maintenance instruction
WV0800-0001; if necessary, replace
conductor rails.
Contact pressure too high.
Install current collector as specified in
Fig. 45.
The power supply gets
interrupted, the contact
is disrupted.
End segment and power terminal are not
properly connected.
Tighten all screws to the specified
torque, see 6.2.5; If necessary, crimp
and install crimp-type socket again, see
6.2.5
Current collector not properly connected.
Install current collector as specified in
Fig. 45; correct connecting cable,
replace if necessary
Contact pressure too low.
Install current collector as specified
in Fig. 45.
Collides with other system components
Check the system's layout, fasten the
affected components in such a way that
they cannot be collided with, replace
damaged components.