![Conductix-Wampfler MultiLine 0835 Mounting Instruction Download Page 69](http://html1.mh-extra.com/html/conductix-wampfler/multiline-0835/multiline-0835_mounting-instruction_2651966069.webp)
Mounting Instruction
Conductor rail system
MultiLine 0835
MAL0835-0001c-EN
www.conductix.com
translated document
page 69 of 81
Functional inspection
:
→
Check for presence of springs
→
Check for correct installation height of the current collector 80 ± 10 mm
(see Fig. 51)
→
Change the fastening position if it is not correct
→
If the fastening position of the current collector is correct, the required contact
force is being exerted. However, if measurement of the contact force is required,
the following steps must be followed:
Attach a suitable spring balance to the current collector arm as close as possible
to the middle joint of the two current collector heads. Pull the current collector
head vertically away from the conductor bar with the spring balance. Reading the
measured value: Check the value measured by the spring balance when the
sliding contact lifts off the sliding surface! The contact force has to be 9 ± 0.5 N!
Check ease of motion of each individual arm of the current collector
→
Clean or completely replace the current collector if necessary
Check the lift and lateral tolerance of the current collector against the conductor
rail
→
Correct the fastening position if necessary
→
Clean the insulation profile or repair damaged places if necessary
Technician