![Conductix-Wampfler MultiLine 0835 Mounting Instruction Download Page 13](http://html1.mh-extra.com/html/conductix-wampfler/multiline-0835/multiline-0835_mounting-instruction_2651966013.webp)
Mounting Instruction
Conductor rail system
MultiLine 0835
MAL0835-0001c-EN
www.conductix.com
translated document
page 13 of 81
DANGER!
Risk of injury from falling or being thrown across the room after an electrical shock!
Work on the following components is dangerous:
Main power supply
Live components:
Power feeds
Cables
Connections
Conductor rail
Connectors
Current collector
Equipment and connections inside switching cabinets
Control systems etc.
Components that have become electrically charged due to a fault
CAUTION!
Before working on these components!
→
Disconnect the conductor rail system
from the power supply according to the 5 safety rules
and
secure it against being switched back on.
For the 5 safety rules, see section 2.6
CAUTION!
Before switching the system on!
→
Every time before the device or system is started, measure the insulation resistance according to
locally applicable technical standards, directives and legal regulations.
→
Perform required country-specific electrical tests
CAUTION!
Maintain electrical safety!
→
Regularly test and maintain electrical equipment
→
If dangerous faults are identified, take measures to correct the faults immediately. Inform the system
operator immediately.
→
If it is not possible to correct a dangerous fault, block off the area in question or turn the equipment
off, and secure it against being switched back on. Inform the system operator immediately
→
Immediately reattach loose and replace damaged cables
→
Always replace burned fuses with equivalent fuses