![Conductix-Wampfler MultiLine 0835 Mounting Instruction Download Page 22](http://html1.mh-extra.com/html/conductix-wampfler/multiline-0835/multiline-0835_mounting-instruction_2651966022.webp)
Mounting Instruction
Conductor rail system
MultiLine 0835
MAL0835-0001c-EN
www.conductix.com
translated document
page 22 of 81
X
Y
X
Z
Fig. 2:
Current collector access
3.2.3
Tolerances
The conductor rail must be installed within the following tolerances. Conductix-Wampfler does not accept any responsibility for the
conductor rail's correct functioning if these tolerances are not observed. In such a case, Conductix-Wampfler does also not accept
any liability for any problems that may arise if the conductor rail system does not function correctly.
Conductor rails
x: ±3 mm; y: ±1 mm (see Fig. 3)
Gap at the connector between 2 conductor bars
z: 2.5 mm + 1 mm per side
Current collector
x: ±10 mm; y: ±10 mm
Force with which the current collector contacts the rail
approx. 9 N
Fig. 3:
Conductor bar 0835 coordinates
Y