![Conductix-Wampfler MultiLine 0835 Mounting Instruction Download Page 49](http://html1.mh-extra.com/html/conductix-wampfler/multiline-0835/multiline-0835_mounting-instruction_2651966049.webp)
Mounting Instruction
Conductor rail system
MultiLine 0835
MAL0835-0001c-EN
www.conductix.com
translated document
page 49 of 81
→
Hold the installation block at against the open
end of the conductor rail.
→
Drive the 2
nd
conductor rail onto the connector
up to stop with the plastic hammer.
CAUTION!
The conductor bars must not be seamlessly
connected to each other. Drive the conductor
bar only up to the stop of the connector pins
(see Fig. 34), leaving a gap of approx. 2.5 mm
(see Fig. 39).
→
Repeat the process until the rail has reached
the projected length minus the two last rail
segments (which corresponds to a gap of
approx. 4 to 8 mm).
→
Check whether 1 or 2 conductor bars and
insulation profiles have to be shortened in order
to achieve the projected length, see section
6.2.5
→
If only the last power rail has to be shortened, it
will be necessary to fit an additional standard
conductor rail (4m).
Fig. 38: Insert the installation block and drive the rail onto the connector
Fig. 39: Gap at connector
Use the QR code (“click“ or “scan“), to watch our animation
Mounting and Connecting Conductor Rails
.
2.5 mm