34
CAUTION
• To prevent scale and/or deposits, after using with detergent, it is best to wash the flow ducts by sucking up some
water.
STOPPING OPERATION: MODELS WITHOUT TOTAL STOP
By closing the delivery line, the motor pump switches to bypass operation and remains in this condition until
the delivery line is opened again.
CAUTION
• Never leave the motor pump in bypass for more than three minutes, and avoid the water re-circulating in the
pump head from overheating, with consequent damage to seals.
STOPPING OPERATION: MODELS WITH TOTAL STOP
By closing the delivery line, the motor pump stops instantly (MTP KTR, MTP KTR Misting, MTP KMR, MTP
KSR, MTP KSR Misting, MTP AXR, MTP AX Misting, MTP LW-K 250, MTP LWR-K 250), or switches to
bypass operation and if it remains in this condition, it stops automatically after about 13 seconds (remaining
motor pumps). The motor pump starts operating again normally as soon as the delivery line is opened.
CAUTION (ONLY MTP AXR AND MTP AX MISTING)
• The Total Stop device does not trip for pressure values below 20-30 bar and, when the delivery line is closed,
the motor pump remains in bypass condition: never leave the motor pump in bypass condition for more than
three minutes and avoid the water re-circulating in the pump head from overheating with consequent damage
to seals.
WARNING
• Remember that when the motor pump is in Total Stop it is operating to all effects, so any accidental start-ups
must be avoided.
• Never leave the motor pump in Total Stop without supervision, even for short periods of time: in this case
perform the stop procedure, making sure no residual pressure remains in the delivery circuit.
STOPPING, CLEANING AND DECOMMISSIONING
WARNING
•
Follow the instructions regarding stopping, cleaning and decommissioning contained in the manual
of the machine in which the motor pump is integrated.
STOP
WARNING
• Always make sure that, once stop operations have been performed, no part of the motor pump and of the
machine in which it is integrated is moving and no pipes contain liquid under pressure.
Perform the stop operations contained in the manual of the machine in which the motor pump is
integrated; unless otherwise indicated, in relation to the motor pump, remember the following.
a) Close the water supply and reset the delivery pressure as described at b) of the
“
STANDARD
OPERATION
(
hIGh
PRESSURE
)”
paragraph.
b)
Remove the plug of the machine integrating the motor pump from the power socket.
c) Wait for the motor pump and the machine in which it is integrated to cool down.
Summary of Contents for MTP AX Misting
Page 2: ...1 2 1 7 2 12 6 9 5 3 4 1 7 2 12 6 9 5 3 4 MTP LW K 250 MTP LWR K 250 MTP ZW K...
Page 3: ...3 4 1 7 2 12 6 9 5 3 4 1 7 2 12 6 9 5 3 4 MTP FW2 MTP RW...
Page 4: ...5 6 7 12 4 9 3 7 12 4 9 3 MTP TW MTP TW Misting MTP TW 500...
Page 5: ...7 8 10 8 12 3 4 1 7 9 12 2 3 4 6 1 5 11 MTP KSR MTP KSR Misting MTP AXR...
Page 6: ...9 10 7 12 4 9 3 7 4 9 3 12 MTP LW Misting MTP FW2 Misting...
Page 7: ...11 12 7 12 2 9 3 4 1 4 12 3 MTP AX Misting MTP KTR MTP KTR Misting...
Page 8: ...13 12 14 1 3 4 12 1 7 2 12 6 9 5 3 4 MTP KMR MTP LW K MTP LWR K MTP ZWR K...
Page 9: ...15 16 8 9 D C B A F E...
Page 88: ...88 RU...
Page 92: ...92 c 60 C 140 F 50 C 122 F MTP KTR MTP KTR Misting MTP KMR MTP KSR MTP KSR Misting 5 C 41 F...
Page 93: ...93 a 8 9 15 b 7 12 5 IEC 60364 1 30 A 30 III RU...
Page 94: ...94 0 1 10 32 8 ft 1 5 2 13 A 2 5 2...
Page 95: ...95 0 RU...
Page 98: ...98 I O...
Page 100: ...100 PRIMING 11 MTP AXR MTP AX Misting Total Stop...
Page 101: ...101 2 RU...
Page 102: ...102 9 ATTENZIONE...