To update the firmware, proceed as follows:
1. Save the firmware file (*.bin) to the local computer;
2. Save the programming using the programming software;
3. Access the “Software Revision” submenu from the Maintenance menu. The screen will show the current panel software
version;
4. Connect the panel to the PC using the USB cable: from Normal USB-A (PC side) to Micro USB-B (panel side);
5. Wait for the PC to recognise the new removable disk;
6. Copy the new update image file (* .bin) into the removable disk folder;
7. Once the image file has been copied, disconnect the removable disk, selecting the Eject option from its dialogue box (right-
click with the mouse and select Eject);
8. If the image file data is correct, the panel starts the firmware update procedure for the main microprocessor, emitting some
short beeps;
9. Disconnect the USB cable;
10. If the fw update was successful the panel will restore itself automatically once it has finished updating.
5.10 Display
This menu offers the option of making some adjustments to the parameters for the touch display of the panel.
•
Coordinates
CAUTION: Touchscreen display calibration must be carried out using a touchscreen (or PALM) stylus.
To proceed with display calibration, select the following in sequence:
SYSTEM – MAINTENANCE – DISPLAY – COORDINATES
Display calibration is performed in 5 steps.
1. The display shows the message: “
Click the circle in upper left-hand corner
”.
The user should press the indicated point in the top left-hand corner of the display 3 times. Then continue with the
Coordinates calibration process.
2. The display shows the message: “
Click the circle in upper right-hand corner
”.
The user should press the indicated point in the top right-hand corner of the display 3 times. Continue with the Coordinates
calibration process.
3. The display shows the message: “
Click the circle in lower right-hand corner
”.
The user should press the indicated point in the bottom right-hand corner of the display 3 times. Continue with the
Coordinates calibration process.
4. The display shows the message: “
Click the circle in lower left-hand corner
”.
The user should press the indicated point in the bottom left-hand corner of the display 3 times. Continue with the
Coordinates calibration process.
5. The display shows the message: “
Click the circle in center
”.
The user should press the indicated point at the centre of the display just once.
If the calibration process was successful, the panel automatically reverts to the initial screen.
If calibration was not successful, the message “
Calibration Unsuccessful!!
” will appear.
The new data entered will be ignored. Perform display calibration again.
82