7.4.21 MaxSpeedLim
[RPM]
The setpoint presets the maximum engine speed in the “Running” operation state. Also see other
conditions in the chapter below.
Step:
1RPM
Range:
MinSpeedLim
- 4000RPM
Default:
2700RPM
7.4.22 BI Speed Sel 1
[RPM]
The setp
oint presets the required engine speed during the ‘Speed Sel 1’ binary input is active.
Function depends on
RetToSpeedAdj
setting.
Step:
1 RPM
Range:
MinSpeedLim
-
MaxSpeedLim
Default:
1250 RPM
7.4.23 BI Speed Sel 2
[RPM]
The setpoint presets the required
engine speed during the ‘Speed Sel 2’ binary input is active.
Function depends on
RetToSpeedAdj
setting.
Step:
1 RPM
Range:
MinSpeedLim
-
MaxSpeedLim
Default:
1300 RPM
7.4.24 BI Speed Sel 3
[RPM]
The setpoint presets the required engine speed during the ‘Speed Sel 3’ binary input is active.
Function depends on
RetToSpeedAdj
setting.
Step:
1 RPM
Range:
MinSpeedLim
-
MaxSpeedLim
Default:
1450 RPM
H
INT
When none of the binary inputs: ‘Speed Sel1’, ‘Speed Sel2’ and ‘Speed Sel3’, ‘Speed Up’ and ‘Speed
Down
’ has not been configured then engine speed is given by the ‘
Engine params:
ECU SpeedAdj
‘
setpoint.
7.4.25 Speed Ramp
[RPM/s]
Any Speed request change is done via this Ramp function. The Ramp via Binary SpeedUp and
SpeedDown inputs is dual rate, see below.