MU-LPNITROX-0919
LP-250-300-600 NITROX
37
- 80
c
b
b
a
c
HP COMPRESSOR
LP-600
LP-300
LP-250
b
b
b
a
ENGLISH
To connect the LP NITROX compressor to a high pressure compressor :
- connect, with a hose (a), the mixer pipe outlet (b) to the intake (c) of the
high pressure compressor;
- fix the hose to the fittings using hose clips.
The PRO O2 Oxygen analyser (a) must be connected with the fittings for
connection of refill hoses (b) of the HP compressors.
Check that there is always a flow regulator (c) between the analyser (a) and
the fittings for connection of the refill hoses (b).
5.3.3
Connection LP compressor-HP compressor
5.3.4
Connecting the PRO O2 Oxygen analyser
IMPORTANT: Use the hose supplied with the compressor.
Never use a hose with a cross-section smaller than the one on
the supplied hose.