6.0
OPERATIONS
6.1
SWITCHING ON/OFF
Once you have turned on the appliance's power, the control panel (3.0
3.0
3.0
3.0) automatically runs a lamp test. The
LEDs and displays come on for a few seconds, after which the display switches "OFF
OFF
OFF
OFF" (control panel is off but
still powered).
Switching on
Switching on
Switching on
Switching on
Hold button
down for a few seconds: the appliance goes into standby
standby
standby
standby. During this phase, the machine
stands by to receive a command.
Display DY1
DY1
DY1
DY1 gives the temperature inside the appliance.
Display DY2
DY2
DY2
DY2 reads "---
---
---
---".
Switching off
Switching off
Switching off
Switching off
Hold button
down for a few seconds: the appliance switches "OFF
OFF
OFF
OFF".
Display DY1
DY1
DY1
DY1 reads "OFF
OFF
OFF
OFF".
Display DY2
DY2
DY2
DY2 stays off.
6.2
BLAST CHILLING/BLAST FREEZING
See points 7777.0
.0
.0
.0 and 8888.0
.0
.0
.0 for details.
6.3
OPENING THE DOOR WHILE A CYCLE IS RUNNING
If the door is opened while a blast chilling/blast freezing cycle is running, the "]]]]----[[[[" code will flash up
intermittently on display DY2
DY2
DY2
DY2 and, at the same time, a buzzer will sound. The compressor and fans inside stop
and only restart once the door is closed.
The blast chilling/blast freezing cycle cannot be started with the door open. If the door stays
The blast chilling/blast freezing cycle cannot be started with the door open. If the door stays
The blast chilling/blast freezing cycle cannot be started with the door open. If the door stays
The blast chilling/blast freezing cycle cannot be started with the door open. If the door stays
open for longer than 30 seconds during the blast chilling/blast freezing cycle, the blast chilling
open for longer than 30 seconds during the blast chilling/blast freezing cycle, the blast chilling
open for longer than 30 seconds during the blast chilling/blast freezing cycle, the blast chilling
open for longer than 30 seconds during the blast chilling/blast freezing cycle, the blast chilling
cycle is stopped.
cycle is stopped.
cycle is stopped.
cycle is stopped.
6.4
PUMP DOWN
Pump
Pump
Pump
Pump----down
down
down
down is a system designed to protect the compressor and its job is to avoid excessive working
pressures during start-up.
Stopping the compressor
Stopping the compressor
Stopping the compressor
Stopping the compressor
When button
is pressed to stop a blast chilling, blast freezing or holding cycle manually, the compressor
keeps working for 5
5
5
5 more seconds.
6.5
TEMPERATURE SENSOR AND NEEDLE PROBE READINGS
While a temperature-based cycle is running, DY1
DY1
DY1
DY1 indicates the value
the value
the value
the value measured by the needle probe. You can
view compartment sensor temperature by pressing the button relating to the cycle selected:
,
or
.
The value is put up on DY1
DY1
DY1
DY1 for 5
5
5
5 seconds.
While a time-based cycle is running, DY1
DY1
DY1
DY1 indicates the value
the value
the value
the value measured by the compartment sensor. You can
view needle probe temperature by pressing button
. The value is put up on DY1
DY1
DY1
DY1 for 5
5
5
5 seconds.
6.6
HEATED NEEDLE PROBE (Optional extra)
The heated needle probe (optional extra) has a device that heats its tip, making it easier to pull out of frozen
products. Holding button
down for 5555 seconds at the end of a blast freezing cycle turns on heating so that
the probe can be easily removed from the frozen product. Heating only comes on if the door is open.
6.7
AUTOMATIC DEFROSTING
During operation, frost forms on the surface of the evaporator: this is normal but it reduces evaporator
efficiency. The purpose of defrosting is to restore full efficiency. Defrosting is performed automatically:
Summary of Contents for W10T
Page 2: ......
Page 22: ...22 Italiano English Deutch Fran ais...
Page 40: ...40 Italiano English Deutch Fran ais...
Page 79: ...79 Italiano English Deutch Fran ais 3 0 3 1 3 2 3 3 3 4 50 430 3 5 3 6 10...
Page 80: ...80 Italiano English Deutch Fran ais 4 0...
Page 91: ...91 Italiano English Deutch Fran ais 1 1 12 0 E0 E0 E0 E0...
Page 94: ...94 Italiano English Deutch Fran ais 14 0 14 1 14 2 1 4 4 2 2 3 4 5 1 2 14 3 1 2 3...
Page 95: ......