Industrivej 62
DK-6740 Bramming
Denmark
Original
Version:
1.0
IceTech R1000H
Alarm List
Page:
5 of 5
Date:
01.05.18
Init:
JM
if the air flow through the heater is restricted.
Contact Cold Jet technical support.
19
Alarm ID=17744
Following error on servo motor.
The unit is blocked and not reaching its position within the
specified time frame. Check if hopper is blocked for shuttle
faults and check if chamber heating is working properly if it’s
an eject fault.
Empty out hoppers and blow dry units in case it has been
stopped with dry ice in the hoppers for a longer period.