Industrivej 62
DK-6740 Bramming
Denmark
Original
Version:
1.0
IceTech R1000H
Alarm List
Page:
3 of 5
Date:
01.05.18
Init:
JM
60 Error , high temperature feeder motor
15
61 Error, Shuttle 1 homing
16
62 Error, Ejector 1 homing
16
63 Error, Shuttle 2 homing
16
64 Error, Ejector 2 homing
16
65 Overheat , Unit 1
17
66 Overheat , Unit 2
17
67 Motor Overheat Unit 1
18
68 Motor Overheat Unit 2
18
69 Alarm ID=17744 , MAIN.X01.G01.U1.M1
19
70 Alarm ID=17744 , MAIN.X01.G01.U2.M1
19
71 Alarm ID=17744 , MAIN.X01.G02.U1.M1
19
72 Alarm ID=17744 , MAIN.X01.G02.U2.M1
19
Trouble shooting table
Troubleshooting Alarm test
Description
1
Emergency_Stop
Emergency stop is active.
Release emergency stop or replace component if damaged.
2
Error
Program error
Contact IceTech technical support.
3
Bus Error
Hardware error
Contact IceTech technical support.
4
Max_ActionTime
Max. actiontime
Contact IceTech technical support.
5
MCB
Error on main circuit breaker.
Check if the main circuit is engaged and if the is a short
circuit / components failure causing the MCB to trip out.
6
Timeout
Timeout.
Investigate what’s causing timeout on component.
7
Sensor failure hopper
Capacitive sensors on the hopper is not active in correct
order.
Check if hopper is blocked or if sensor sensitivity needs to be
Summary of Contents for 514635
Page 1: ...User s Manual Technical file 1 2 User s manual IceTech R1000H...
Page 2: ...User s Manual 1 User s manual IceTech R1000H...
Page 27: ...Technical file 2 User s manual IceTech R1000H...
Page 29: ...Table for mechanical maintenance 1 Technical File IceTech R1000H...
Page 33: ...Procedures for maintenance and repair 2 Technical File IceTech R1000H...
Page 66: ...Alarm list 3 Technical File IceTech R1000H...
Page 72: ...P I Diagram 4 Technical File IceTech R1000H...
Page 77: ...Assembly drawings 5 Technical File IceTech R1000H...