Industrivej 62
DK-6740 Bramming
Denmark
Original
Version:
1.0
IceTech R1000H
Alarm List
Page:
4 of 5
Date:
01.05.18
Init:
JM
adjusted.
8
Wrong tool
Sensor for tool detection is in wrong state.
Check that recipe is according to installed tool. Check if
sensor need adjustment.
9
Error , Low air pressure
Check if instrument air is properly connected.
Air pressure must be higher than the minimum air pressure
set point.
10
Hydraulic oil
temperature high
Hydraulic oil temperature is too high. Check for hydraulic oil
leaks and oil level on the hydraulic tank if replenishing is
needed.
Do not restart production before oil temperature has
dropped to acceptable level (<50°C).
11
Hydraulic oil pressure
high
Hydraulic pressure is higher than set point and needs
adjustment.
Contact Cold Jet technical support.
12
Error , hydraulic motor
for pump
Program fault
Contact Cold Jet technical support.
13
Running Time
Running time warning. Service interval exceeded.
Contact Cold Jet technical support.
14
Max standby time
Max. standby time exceeded. Clear outlet conveyor and run
an emptying cycle. Clear out dry ice in hopper in case it is
blocked.
15
Error , high temperature
feeder motor
Feeder conveyor has too high temperature and is stopped.
Please investigate ampere consumption and if the conveyor
is running with increased friction/load.
16
Error, … homing
The unit is not able to home properly.
Contact Cold Jet technical support.
17
Overheat
Chamber heating is above max. set point.
Check if set point is too high or if the air flow through the
heater is restricted.
18
Motor Overheat
Heater motor is overheated. Check if set point is too high or
Summary of Contents for 514635
Page 1: ...User s Manual Technical file 1 2 User s manual IceTech R1000H...
Page 2: ...User s Manual 1 User s manual IceTech R1000H...
Page 27: ...Technical file 2 User s manual IceTech R1000H...
Page 29: ...Table for mechanical maintenance 1 Technical File IceTech R1000H...
Page 33: ...Procedures for maintenance and repair 2 Technical File IceTech R1000H...
Page 66: ...Alarm list 3 Technical File IceTech R1000H...
Page 72: ...P I Diagram 4 Technical File IceTech R1000H...
Page 77: ...Assembly drawings 5 Technical File IceTech R1000H...