Procedure step by step
1.
Dismount the 4 screws
[
1
]
from the return oil filter housing
[
4
]
.
2.
Remove the housing top plate
[
2
]
.
3.
Take out the return oil filter cartridge and replace it with a new one. Be careful not to
make any damage while replacing it into the housing.
4.
Assemble again by placing the housing top plate
[
2
]
on top of the return oil filter housing
[
4
]
.
5.
Mount the 4 screws
[
1
]
again tightening evenly and firmly.
BEFORE STARTING PRODUCTION THE HYDRAULIC STATION SHOULD BE CHECKED IN SINGLE MODE!
Operating in single mode control
Check that there are no leaks on the hydraulic station.
4 Move the pistons using the
arrow buttons
1 Select single mode
3 Start the hyd. pump
2 Enter Manual operation
controls