9. Put the coaxial ADU cable through the protection plate as shown in
the following figure, and connect the N connector of the ADU cable
to the ADU.
Select a suitable size for the cable gland: 16—20 mm diameter or
19—23 mm diameter. See also
N-connector interface on the ADU
on page A-8 for a more detailed drawing how to connect the N-
connector on the ADU.
Ensure that the connector assembly is properly protected against
seawater and corrosion. As a minimum, wrap it with self-
amalgamating rubber.
10.Put the protection plate in place and fasten the 4 bolts (picture 5).
11.Fasten the nut (picture 6).
Where the cables are exposed to mechanical wear — on deck, through
bulkheads, etc. — protect the cables with steel pipes. Otherwise, follow
standard procedures for cabling in ship installations.