Status signalling with LEDs and status messages
8-10
Chapter 8: Service & maintenance
98-133966-G1
During service and maintenance, one of the following system status
messages may be shown:
• Service switch
• Azimuth calibration
• TX cable calibration
• XIM data error
8.3.2
LEDs of the ADU modules
Each ADU module has a Power and a Service LED.
For a list of modules see
Removal and replacement of ADU modules
8.3.3
LEDs in the ACU
The ACU has 3 LEDs: Power, Logon and Fail/Pass LED.
LED
Behavior
Description
Power
Steady green
Power supply OK
Off
No power
Service Steady green
Module ok, application running.
Flashing green
Waiting for upload
Flashing red/green
Uploading application
Steady red
Module error or loading error
Table 8-1: LEDs of the ADU modules
Figure 8-8: LEDs on the ACU
LEDs
LED
Behavior
Description
Power
Steady green
Power supply OK
Steady red
Power supply failure
Off
No power
Table 8-2: LEDs on the ACU