Alternative grounding for fibre glass hulls
98-133966-G1
Appendix F: Grounding and RF protection
F-9
FFFF
Grounding and RF
F.5.2
Grounding the ADU
If the mounting base of the ADU is electrically connected to any other
ground potential than the ACU (e.g. Lightning Ground), the ADU must
be isolated at its mounting bolts by means of shoulder bushings and
washers - see section F.6.3.
However, a ground connection must be established via one of the
mounting bolts using a separate ground cable. The ground cable must
be routed parallel and in close proximity to the shielded coax cable
hence connecting the ADU to the ACU Grounding kit. A heavy gauge
wire with tinned strands (min. 6 mm
2
) can be used for this purpose.
Figure F-5: Alternative grounding for fibreglass hulls
7HUPLQDO
5)*URXQG3ODWH
+HDY\*DXJH:LUH
$QWHQQD
7HUPLQDO*URXQGLQJ.LW
SAILOR900TM.book Page 9 Monday, September 16, 2013 11:01 AM