Updating VIM/PCM calibration data
8-98
Chapter 8: Service & maintenance
98-133966-G1
8.6
Updating VIM/PCM calibration
data
After installing a new VIM (VSAT Interface Module) or PCM (Pedestal
Control Module) you must update the calibration data.
The ACU does not know which of the two modules (PCM or VIM) has
been replaced. The ACU needs to know which set of data to keep. You
must select the
module that was not exchanged
so the calibration
data can be copied to the module that was exchanged during service.
1. Enter the web interface (http://192.168.0.1) and click
SERVICE
>
XIM DATA
. A screen similar to the one in the figure below will
appear:
2. The figure shows at
Unit-no
Unit-Serial-Number for the PCM,
because this module was exchanged during service. In this case the
user must press the select button below the VIM module in order to
copy the current calibration data to the new PCM module.
3. Click
Select
, then a warning will appear.
4. Click
OK
to continue, the data is copied into the replaced module.
5. Click
Refresh
. When the XIM data has been successfully copied
from one module to the other, the web interface displays a window
Figure 8-134: Updating VIM/PCM calibration data (example)
Important
Select always the XIM data for the module that was
not
exchanged.
Figure 8-135: XIM data, warning
Figure 8-136: XIM data not ready
SAILOR900TM.book Page 98 Monday, September 16, 2013 11:01 AM
Summary of Contents for Sailor 900 VSAT
Page 2: ...98 138976 A Cover_SAILOR 900 VSAT System_407090B indd 2 15 04 2013 15 54 39 ...
Page 28: ...List of tables xxvi 98 133966 G1 SAILOR900TM book Page xxvi Monday September 16 2013 11 01 AM ...
Page 257: ...Appendices SAILOR900TM book Page 1 Monday September 16 2013 11 01 AM ...
Page 258: ...SAILOR900TM book Page 2 Monday September 16 2013 11 01 AM ...
Page 355: ...98 138976 A Cover_SAILOR 900 VSAT System_407090B indd 3 15 04 2013 15 54 40 ...