iv
98-133966-G1
Compass Safe Distance:
SAILOR 900 VSAT antenna or ADU (Above Deck Unit): min. 130 cm (Var. A), 170 cm (Var. B)
(IEC 945).
SAILOR 900 VSAT ACU (Antenna Control Unit): min. 10 cm (IEC 945)
Service
User access to the interior of the ACU is prohibited. Only a technician authorized by Cobham
SATCOM may perform service - failure to comply with this rule will void the warranty.
Access to
the interior of the Above Deck Unit is allowed. Replacement of certain modules - as described in
on page 8-1 and general service may only be performed by a
technician authorized by Cobham SATCOM.
Do not service or adjust alone
Do not attempt internal service or adjustments unless another person, capable of rendering first
aid resuscitation, is present.
Grounding, cables and connections
To minimize shock hazard and to protect against lightning, the equipment chassis and cabinet
must be connected to an electrical ground. The ACU must be grounded to the ship. For further
grounding information refer to the Installation manual.
Do not extend the cables beyond the lengths specified for the equipment. The cable between
the ACU and Above Deck Unit can be extended if it complies with the specified data
concerning cable losses etc.
Rx and Tx cables for the SAILOR 900 VSAT system are shielded and should not be affected by
magnetic fields. However, try to avoid running cables parallel to high power and AC/RF wiring as
it might cause malfunction of the equipment.
Power supply
The voltage range for the SAILOR 900 VSAT is 20 — 32 VDC. Note that the Above Deck Unit is
powered by the ACU.
If a 24 VDC power bus is not available, an external 115/230 VAC to 28 VDC power supply can
be used, for example a SAILOR 6080 Power Supply.
Do not operate in an explosive atmosphere
Do not operate the equipment in the presence of flammable gases or fumes. Operation of any
electrical equipment in such an environment constitutes a definite safety hazard.
Keep away from live circuits
Operating personnel must not remove equipment covers. Component replacement and internal
adjustment must be made by qualified maintenance personnel. Do not replace components
with the power cable connected. Under certain conditions, dangerous voltages may exist even
with the power cable removed. To avoid injuries, always disconnect power and discharge
circuits before touching them.
Failure to comply with the rules above will void the warranty!
SAILOR900TM.book Page iv Monday, September 16, 2013 11:01 AM
Summary of Contents for Sailor 900 VSAT
Page 2: ...98 138976 A Cover_SAILOR 900 VSAT System_407090B indd 2 15 04 2013 15 54 39 ...
Page 28: ...List of tables xxvi 98 133966 G1 SAILOR900TM book Page xxvi Monday September 16 2013 11 01 AM ...
Page 257: ...Appendices SAILOR900TM book Page 1 Monday September 16 2013 11 01 AM ...
Page 258: ...SAILOR900TM book Page 2 Monday September 16 2013 11 01 AM ...
Page 355: ...98 138976 A Cover_SAILOR 900 VSAT System_407090B indd 3 15 04 2013 15 54 40 ...