- 391 -
4.2.4 MSW4
●MSW4-1: Automatic length measurement
[Outline] In selecting black mark paper, set the enable/disable of automatic length measurement.
(Black mark/label support model only)
OFF(0)
ON(1)
BM Measure
Invalid
Valid
ON (1) OPERATION: Automatic length measurement is enabled.
At power-up, measurement operation is taken.
OFF (0) OPERATION: Automatic length measurement is disabled.
Operation follows the value set by <GS l>.
●MSW4-2: Black mark sensor position
[Outline] Selects black mark sensor position.
(CT-S300/CT-S310 unique)
OFF(0)
ON(1)
BM sensor position
surface
back
ON (1) OPERATION: Black mark sensor detects a black mark on the printing surface.
OFF (0) OPERATION: Black mark sensor detects a black mark on the printing back.
●MSW4-2
:
Searching top of form at power on.
[Outline]
Set the enabled/disabled of the function to search the top of form at power on.
(CT-S281/CT-S2000/CT-S4000 unique)
OFF(0)
ON(1)
Power on TOF
Invalid
Valid
ON (1) OPERATION:
Searching top is enabled
OFF (0) OPERATION:
Searching top is disenabled
**This function is valid only on label models or black mark models.
** This function is invalid when thermal paper is selected on MSW4-4.