- 137 -
(1)GS k m [d1...dk] NUL
(2)GS k m n [d1...dn]
Support model
CT-S280
CT-S300
CT-S2000
CT-S4000
CT-S251
CT-S281
CT-S310
CT-S801/851
CT-S601/651
CT-P29x series
CT-S310 II
[Function]
Printing the bar code
[Code]
(1)<1D>H<6B>H<m> [d1…dk] NULL
(2)<1D>H<6B>H<m><n> [d1…dn]
[Range]
(1)0≤m≤6
The definitions of “k” and “d” vary with the bar code system.
[The specification which depend on the model]
CT-S280
/
CT-S281
/
CT-S300
/
CT-S310
/
CT-S2000
/
CT-S4000
/
CT-P29x series
(2)65≤m≤73
The definitions of “n” and “d” vary with the bar code system.
CT-S801(II)
/
CT-S851(II)
/
CT-S601(II)
/
CT-S651(II)
/
CT-S310II
/
CT-S251
(2)65≤m≤73, 75≤m≤78 The definitions of “n” and “d” vary with the bar code system.
[Outline]
[The specification which is common to the model]
• Selects a bar code system and prints the bar code.
For (1):
m
Bar Code System
Range of “k”
Range of “d”
0
UPC-A
11≤k≤12
48≤d≤57
1
UPC-E
11≤k≤12
48≤d≤57
2
JAN13(EAN)
12≤k≤13
48≤d≤57
3
JAN8(EAN)
7≤k≤8
48≤d≤57
4
CODE39
1≤k
48≤d≤57, 65≤d≤90
32, 36, 37, 43, 45, 46, 47
5
ITF
1≤k (An even number)
48≤d≤57
6
CODABAR
1≤k
48≤d≤57, 65≤d≤68
36, 43, 45, 46, 47, 58
For (2):
m
Bar Code System
Range of “n”
Range of “d”
65 UPC-A
11≤n≤12
48≤d≤57
66 UPC-E
11≤n≤12
48≤d≤57
67 JAN13(EAN)
12≤n≤13
48≤d≤57
68 JAN8(EAN)
7≤n≤8
48≤d≤57
69 CODE39
1≤n≤255
48≤d≤57, 65≤d≤90
32, 36, 42, 43, 45, 46, 47
70 ITF
1≤n≤255
(An even number)
48≤d≤57
71 CODABAR
1≤n≤255
48≤d≤57, 65≤d≤68
36, 43, 45, 46, 47, 58
72 CODE93
1≤n≤255
0≤d≤127
73 CODE128
2≤n≤255
0≤d≤127
75 GS1 DataBar mnidirectional
n=13
48≤d≤57
76 GS1 DataBar Truncated
n=13
48≤d≤57
77 GS1 DataBar Limited
n=13
48≤d≤57
78 GS1 DataBar Expanded
2≤n≤255
0≤d≤127