- 218 -
CT-S300
• a=202: Controls input buffer full Busy with the value selected by
(nL+nH×256) and controls Busy with output/cancel timing
(remaining capacity).
(nL+nH×256)
When Input Buffer
Capacity “Small” is Set
When Input Buffer
Capacity 4K Bytes
(Large) is Set
Output
Cancel
Output
Cancel
1 (Default)
16
26
128
256
2
16
40
128
512
3
30
50
72
256
4
30
60
72
512
• XON/XOFF is also output by the establishment of conditions.
• Ignores the data received when input buffer idle capacity is 0.
• a=220: Sets the maximum width of black mark by the amount selected by
(nL+nH×256)
1≤(nL+nH×256)≤32767
Unit: 1 dot
Initial value: 40 dots
• a=221: Sets the maximum length of black mark page with the value
selected by (nL+nH×256).
1≤(nL+nH×256)≤32767
Unit: 1 dot
Initial value: 2360 dots
• a=222: Head margin set by the value selected by (nL+nH×256).
1≤(nL+nH×256)≤32767
Unit: 168dot
Initial value: 0dot
• a=223: Sets black mark bottom margin with the amount selected by
(nL+nH×256).
1≤(nL+nH×256)≤255
Unit: 1 dot
Initial value: 34 dots
• a=224: Sets cut distance with the value selected by (nL+nH×256).
1≤(nL+nH×256)≤255
Unit: 1 dot
Initial value: 232 dots
• a=225: Sets head distance with the value selected by (nL+nH×256).
1≤(nL+nH×256)≤255
Unit: 1 dot
Initial value: 56 dots