Cisco TelePresence System 1100 Assembly, First-Time Setup, and Field Replaceable Unit Guide
OL-19695-01
Chapter 3 Assembling and Mounting a Cisco TelePresence System 1100
Important Warnings and Cautions
Figure 3-1
CTS 1100 Wall Requirements
206222
Drywall
Steel Stud (2 x 4 / 25ga minimum)
Stud type and structural strength must conform to the North American
Specification for the Design of Cold-Formed Steel Structural Members.
[362 S 125 18, C-Shaped, S-Stud Section]
1/2" minimum
Drywall Thickness
(Both Sides of Stud)
16" or 24" (on center) Studs
Display Mount Installation Location
(Must be centered on stud)
If back side of wall is unfinished, drywall must be installed
to a minimum of one stud left and right of the stud(s)
being used to install the mount. Drywall must be
secured to studs with screws 12" on center
There must be a minimum of
2 1/4 inches (57mm)
clearance inside wall
Front